York MP SERIES Technical Manual

York MP SERIES Technical Manual

Modular psc air handlers

Advertisement

Quick Links

TECHNICAL GUIDE
MODULAR PSC AIR HANDLERS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: MP SERIES
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at:
www.upgnet.com and www.york.com
Additional rating information can be found at:
www.ahridirectory.org
WARRANTY SUMMARY
Standard 5-year limited parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replacement
or closing for new home construction.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
® ®

DESCRIPTION

This unique modular system allows the flexibility to handle any
application. These versatile MP blowers may be used for
upflow, downflow, or horizontal left or right applications. They
may be combined with cased coils to function as a cooling only
unit or with a heat pump including electric heat for 1 and 3
phase applications.

FEATURES

COMMON MP AIR HANDLER AND MATCH-UP CM COIL
Rigid Case Construction - An interior endoskeleton for
structural support, smooth sides, and locks in insulation.
Powder-painted - G30 galvanized steel case provide a coated
edge that resists corrosion and rust creep.
Quality Construction - Structural components are made of
Aluminum or G90 galvanized steel to prevent corrosion.
Improved Insulation Design - Single piece with no external
screws to reduce thermal transmission paths to prevent
sweating. Foil faced insulation for ease of cleaning.
Case Depth - These models have 20.5" casing which provide
ease of attic access and tight applications.
MP AIR HANDLERS
Factory Sealed - Achieves 2% or less total airflow leakage rate
at duct leakage test conditions in positive and negative
pressure for system airflow verification.
Electric Heat Kits - 6HK series of field installed electric heat
kits are available for installation-friendly and easy service
applications.
Blowers - All models use direct-drive, multi-speed PSC motors.
CM COILS
TM
MaxAlloy
Coil - Long life aluminum coils built to deliver
lasting performance, efficiency and reliability.
Thermostatic Expansion Valve - The accessory chatleff style
TXV provides easy installation to convert the indoor coil to the
required refrigerant that does not require brazing to replace or
install. Some models are available with factory installed TXV.
Thermoset Drain Pan - Low retention and positive slope for
drainage to reduce potential mold or contaminants.
Accessories - A full line of matching accessories available for
use with the blower and coils to provide for any type of
application.
5006167-YTG-F-0517

Advertisement

Table of Contents
loading

Summary of Contents for York MP SERIES

  • Page 1: Description

    COOLING & HEAT PUMPS Powder-painted - G30 galvanized steel case provide a coated MODELS: MP SERIES edge that resists corrosion and rust creep. Quality Construction - Structural components are made of Aluminum or G90 galvanized steel to prevent corrosion.
  • Page 2: Table Of Contents

    5006167-YTG-F-0517 LIST OF SECTIONS NOMENCLATURE DESCRIPTION ......... . 1 PRODUCT TYPE M = Modular Blower FEATURES .
  • Page 3: Dimensions & Duct Connection Dimensions

    5006167-YTG-F-0517 DIMENSIONS & DUCT CONNECTION DIMENSIONS DIMENSIONS - MP MODULAR AIR HANDLERS & CM MULTI-POSITION FULL CASED COILS Dimensions Height Width Opening Widths Wiring Knockouts Models Power Control MP08BN21 21-1/2 17-1/2 16-1/2 16-1/2 MP12BN21 21-1/2 17-1/2 16-1/2 16-1/2 7/8 (1/2), MP14DN21 22-1/2 24-1/2...
  • Page 4: Cooling Capacity

    5006167-YTG-F-0517 COOLING CAPACITY MBH@ Evap. Temp. and Corresponding R-410A Pressure (°F/PSIG) Entering Air Models Rated CFM Dry/Wet Bulb (°F) 35/107.9 40/118.9 45/130.7 50/143.3 85/72 45.7 41.6 36.8 30.5 80/67 38.5 33.9 28.5 22.3 CM18B 75/62 31.5 26.5 20.5 15.9 70/57 24.4 19.5 15.2...
  • Page 5: Physical & Electrical Data - Cooling Only

    5006167-YTG-F-0517 COOLING CAPACITY (Continued) MBH@ Evap. Temp. and Corresponding R-410A Pressure (°F/PSIG) Entering Air Models Rated CFM Dry/Wet Bulb (°F) 35/107.9 40/118.9 45/130.7 50/143.3 85/72 108.0 98.4 88.1 73.8 80/67 93.3 82.1 69.7 57.0 CM48C 1400 75/62 75.9 64.4 53.1 41.9 70/57 60.7...
  • Page 6: Electrical Heat - Minimum Fan Speed

    5006167-YTG-F-0517 ELECTRICAL HEAT - MINIMUM FAN SPEED Heater Kit Air Handler Models Nom. kW 1,2,3 @240V Models MP08B MP12B MP14D MP16C MP20D 6HK(0,1)6500206 2.4kW 6HK(0,1)6500506 4.8kW 6HK(0,1)6500806 7.7kW 6HK(0,1)6501006 9.6kW 6HK36501025 6HK(1,2)6501306 12.5kW 6HK(1,2)6501506 14.4kW – 6HK36501525 6HK(1,2)6501806 17.3kW – 6HK36501825 6HK(1,2)6502006 19.2kW...
  • Page 7: Electrical Data For Single Source Power Supply: 208/230-1-60

    5006167-YTG-F-0517 ELECTRICAL DATA FOR SINGLE SOURCE POWER SUPPLY: 208/230-1-60 Field Wiring Heater Heater Air Handler Amps Min. Circuit Ampacity MOP. Models Models @240V 208V 230V 208V 230V 6HK(0,1)6500206 12.6 13.7 6HK(0,1)6500506 23.4 25.7 MP08B 6HK(0,1)6500806 36.6 40.3 6HK(0,1)6501006 45.0 49.6 6HK(1,2)6501306 58.2 64.3...
  • Page 8: Electrical Data For Multi-Source Power Supply: 208/230-1-60

    5006167-YTG-F-0517 ELECTRICAL DATA FOR MULTI-SOURCE POWER SUPPLY: 208/230-1-60 Min. Circuit Ampacity MOP. Heater 208V 230V 208V 230V Air Handler Heater Amps Models Models Circuit Circuit @240V MP08B 6HK16501306 20.5 37.6 22.5 41.5 6HK16501306 22.0 37.6 24.0 41.5 6HK16501506 24.9 43.3 27.2 47.9 MP12B...
  • Page 9: Electrical Data For Multi-Source Power Supply: 208/230-3-60

    5006167-YTG-F-0517 ELECTRICAL DATA FOR MULTI-SOURCE POWER SUPPLY: 208/230-3-60 Min. Circuit Ampacity MOP. Heater Heater 208V 230V 208V 230V Air Handler Amps Models Circuit Circuit Models @240V MP12B 6HK46502025 46.2 28.3 25.0 30.9 27.6 MP14D 6HK46502025 46.2 28.5 25.0 31.1 27.6 MP16C 6HK46502025 46.2...
  • Page 10: Accessories

    Thermostat - Compatible thermostat controls are available SINGLE SOURCE POWER ACCESSORY (THREE PHASE) through accessory sourcing. For optimum performance, these outdoor units are fully compatible with our York touch screen Contains a terminal block and wiring to S1-32436041000 connect service disconnects together.
  • Page 11: Combustible Floor Base Accessory

    5006167-YTG-F-0517 COMBUSTIBLE FLOOR BASE ACCESSORY AIR HANDLER DEPTH FRONT DOWNFLOW FLOOR AIR HANDLER APPROX. 1/2” WARM AIR PLENUM CLEARANCE 11” ALL AROUND with 1” flange out PLENUM on each side. 1” 13” FLOOR OPENING FIBERGLASS CROSS SECTION (A-A) FROM SIDE INSULATION FIBERGLASS TAPE under flange.
  • Page 12: Typical Thermostat Connection

    5006167-YTG-F-0517 TYPICAL THERMOSTAT CONNECTION FIELD INSTALLED JUMPER IF SINGLE STAGE THERMOSTAT IS USED. A0370-002 Johnson Controls Unitary Products...
  • Page 13: Air Flow Data - Cfm (208 Volt)

    5006167-YTG-F-0517 AIR FLOW DATA - CFM (208 Volt) External Static Pressure (in. WC.) Blower Models CM Models Motor Speed 0.10 0.20 0.30 0.40 0.50 0.60 0.70 208 Volt High CM18B Medium MP08B High CM24B Medium High 1459 1410 1342 1275 1200 1129 1022...
  • Page 14: Air Flow Data - Cfm (230 Volt)

    For optimal performance, external static pressures of 0.2" to 0.5" are recommended.  Heating applications tested at 0.50” w.c. esp. Subject to change without notice. Published in U.S.A. 5006167-YTG-F-0517 Copyright © 2017 by Johnson Controls, Inc. All rights reserved. Supersedes: 5006167-YTG-E-1116 York International Corp. 5005 York Drive Norman, OK 73069...

Table of Contents