Clearance To Combustibles; Floor Protection - Monessen Hearth SD30PV Installation & Operating Manual

Sundance vent free gas heater
Table of Contents

Advertisement

C. Clearance to Combustibles
Minimum Clearances to Combustible Materials
Maintain clearance, (empty space), between combustible
materials and the heater as specified below for the appropriate
firebox shell being installed.
B
A
Ceiling
B
Side Wall
ST101
Min. Clrnc
C
Rear Wall
4/15/99 djt
D
Max. Alcove Depth
S
T
U
V
Mantel
Ref
Shelf Depth
A
13" (330mm)
B
11-1/4" (286mm)
C
9-3/8" (241mm)
D
7-1/2" (191mm)
FP599a
E
5-3/4" (146mm)
stove mantel heights
9/27/99 djt
F
4" (102mm)
G
2-1/4" (57mm)
H
1" (25mm)
5
D
A
C
35" (889mm)
2" (51mm)
0" (0mm)
13" (330mm)
A
B
C
D
E
F
G
W
X
H
Y
Z
Mantel from
Ref.
Stove Top
S
35" (889mm)
T
30" (762mm)
U
25" (635mm)
V
20" (508mm)
W
15" (381mm)
X
10" (254mm)
Y
5" (127mm)
Z
2" (51mm)
Monessen • Sundance VF Installation Manual_R1 • 04/17
D. Floor Protection
The Sundance must be installed on rigid flooring. If the
appliance is installed on any combustible surface other than
wood flooring, such as carpet or tile, a metal or wood panel
must be installed to extend the full length and width of the unit.
!
• Do not install this heater in a bathroom or bedroom.
• Installation of this heater must conform with local codes
or, in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1 / NFPA54.
• This heater creates warm air currents. These currents
move heat to wall surfaces next to the heater. Installing
the heater next to vinyl or cloth wall coverings or
operating the heater where impurities in the air such
as tobacco smoke exist, may discolor walls.
• Do not use a blower insert, heat exchanger insert or
other accessory not approved for use with this heater.
WARNING