W W A A R R N N I I N N G G : : The Impulse 1015P is extremely efficient and powerful! This sound system can permanently damage
hearing! Use extreme care setting the overall maximum loudness!
The apparent sound level of the Impulse 1015P can be deceiving due to its clear, clean sound output. The lack of
distortion or obvious distress can make the sound level seem much lower than it actually is. This system is
capable of SPLs in excess of 130 dB at 1 meter from the speaker!
U U S S I I N N G G T T H H E E I I M M P P U U L L S S E E 1 1 0 0 1 1 5 5 P P
F F L L Y Y I I N N G G T T H H E E I I M M P P U U L L S S E E 1 1 0 0 1 1 5 5 P P
C C a a u u t t i i o o n n : : Suspending or flying the Impulse 1015P must be done by a certified structural engineer.
I I m m p p o o r r t t a a n n t t S S a a f f e e t t y y I I n n f f o o r r m m a a t t i i o o n n f f o o r r M M o o u u n n t t i i n n g g t t h h e e P P e e a a v v e e y y I I m m p p u u l l s s e e 1 1 0 0 1 1 5 5 P P s s p p e e a a k k e e r r s s y y s s t t e e m m s s . .
C C a a u u t t i i o o n n : : Before attempting to suspend the Impulse 1015P, consult a certified structural engineer. This speaker
can fall due to improper suspension, resulting in serious injury and property damage. Other enclosures must not
be suspended below one, nor should additional weight be suspended from one of these units. Use only the
correct mating hardware. All associated rigging is the responsibility of others.
Always use all four inserts of a given group as a set; NEVER use just one insert to fly a cabinet! The four insert
groupings contain a top group of four and a bottom group of four, but some models also have a group of four on
the rear plane of the cabinet.
Maximum enclosure angle from vertical hang: 30˚
Always loop a suitable safety chain or wire rope through the top handle of the unit and firmly attach to a suitable
structural member as indicated by a certified structural engineer.
The recommended range of torque for the mounting bolt is 3 to 3-1/2 lb./ft. of torque. DO NOT OVERTIGHTEN! If
an insert spins, it has been damaged and the cabinet cannot be flown!
Never transport the cabinet while it's mounted on an array bracket or other mounting bracket, as this may
unduly stress the mounting inserts.
W W A A R R N N I I N N G G ! ! ( ( n n o o t t e e t t o o s s t t r r u u c c t t u u r r a a l l e e n n g g i i n n e e e e r r ) )
For the Impulse 1015P, the thread insertion depth of the end of the mounting bolt should not be more than 1/2"
past the surface of the cabinet. If these thread insertion depths are exceeded, then the inserts may be damaged
or unseated from the cabinet, severely compromising the mounting integrity of the cabinet!
The correct mounting bolt diameter and threads per inch are: 1/4" X 20. Use of a grade five bolt is
recommended.