XVM-B62
Setting Method:
1. Turn off power.
2. While holding the TEST switch (S408) down for more than 5
seconds, turn on power. Then, release the TEST switch (S408).
3. TEST MODE MENU is indicated.
Terminating Method:
Select the MENU No. 7, SOFT REST using the [MENU] button and
determine the selection using the [POWER] button.
The FOR FACTORY Mode:
The FOR FACTORY mode can be used to perform 12 different
adjustment items with the remote controller.
1. Select the MENU No. 2, FOR FACTORY using the [MENU]
button and determine the selection using the [POWER] button.
2. The FOR FACTORY mode is now entered. The following items
are selected in turn by pressing the [POWER] button repeatedly.
Com Gain
Y Gain
Black Limt
White Limt
R-Sub BRT
B-Sub BRT
R-Sub CONT
B-Sub CONT
Gamma1
Gamma2
VCO Free Run
H Pos
3. For each item selected, adjust so that the adjustment value is
within the specified value range using the [INPUT/+] and
[DIMMER/--] buttons on the remote controller.
4. After adjustment, press the [MENU] button to determine the
adjustment value. Press the [MENU] button once more to change
to the next item.
5. After all necessary adjustments are completed, select EXIT
using the [MENU] button and press the [POWER] button to display
the MENU screen. Then, select No.7, SOFT REST using the
[MENU] button and determine the selection using the [POWER]
button to terminate the TEST mode.