Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 456

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Setting
Signal
Positive
Negative
name
logic
logic
93
193
Y93
94
194
ALM2
95
195
Y95
96
196
REM
97
197
ER
98
198
LF
99
199
ALM
200
300
FDN2
201
301
FUP2
202
302
RL2
203
303
PID2
SLEEP
204
304
2
205
305
Y205
206
306
Y206
207
307
Y207
208
308
PS
211
311
LUP
212
312
LDN
213
313
Y213
9999
*1
Note that changing the frequency setting with an analog signal or the setting dial on the operation panel (FR-DU08) may cause the turning ON
and OFF of Up to frequency (SU) signal depending on its changing speed and the timing of the speed change determined by the acceleration/
deceleration time setting. (The signal state changing does not occur when the acceleration/deceleration time is set to 0 seconds.)
*2
This signal is available only for the standard model.
*3
This signal cannot be assigned to any of the output terminals for plug-in options (FR-A8AY and FR-A8AR).
*4
This signal is available when the compatible plug-in option or control terminal option is installed.
*5
This signal is available for the standard model or the IP55 compatible model.
Function
Current average monitor
Fault output 2
Maintenance timer signal
Remote output
Alarm output 2
Alarm
Fault
Second PID lower limit
Second PID upper limit
Second PID forward/reverse
rotation output
Second During PID control
activated
During second PID output
shutoff
Second PID deviation limit
Cooling fan operation
command
Control circuit temperature
PU stopped
Upper limit warning detection
Lower limit warning detection
During load characteristics
measurement
(No function)
Operation
Outputted in pulses for transmission of the
average current value and the maintenance
timer value. This signal cannot be assigned
to any of the relay output terminal (Pr.195,
Pr.196, Pr.320 to Pr.322).
Outputted when the inverter's protective
function is activated to stop the power output
(when the Fault occurs). The signal output
continues during the inverter reset and stops
*7
after the inverter reset finishes.
Outputted when the value of Pr.503 reaches
the Pr.504 setting or higher.
Outputted via a terminal by setting a proper
number in a relative parameter.
The ER signal output follows the ALM signal
output when Pr.875 = "0 (initial value)".
When Pr.875 = "1" and when any of E.OHT,
E.THM, or E.PTC occurs, the inverter
decelerates the motor to a stop at a time of
the ER signal ON. When any of other faults
occurs, the ER signal outputs when the
inverter output stops.
Outputted when an Alarm (Fan alarm) or a
communication error occurs.
Outputted when the inverter's protective
function is activated to stop the power output
(when the Fault occurs). The signal output
stops when the inverter reset starts.
Outputted when the input value is lower than
the lower limit set for the second PID control
operation.
Outputted when the input value is higher
than the upper limit set for the second PID
control operation.
Outputted during forward rotation operation
in the second PID control operation.
Outputted during the second PID control
operation.
Outputted while the second PID output
suspension function is activated.
Outputted when the absolute deviation value
exceeds the limit value during the second
PID control operation.
Output when the cooling fan operation is
commanded.
Outputted when the temperature of the
control circuit board reaches the detection
level or higher.
Output while the PU is stopped.
Output when the load fault upper limit
warning is detected.
Output when the load fault lower limit
warning is detected.
Output during measurement of the load
characteristics.
5.11 (M) Item and output signal for monitoring
Refer
Related
to
parameter
page
Pr.555 to Pr.557
346
460
Pr.503, Pr.504
345
Pr.495 to Pr.497
466
Pr.875
401
402,
Pr.121, Pr.244
630
460
Pr.753 to Pr.758
570
Pr.753 to Pr.758,
Pr.1147 to
Pr.1149
Pr.753 to Pr.758,
Pr.1145, Pr.1146
Pr.244
402
Pr.663
471
Pr.75
320
Pr.1480 to
417
Pr.1492
455
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10

Hide quick links:

Advertisement

Table of Contents
loading