Download Print this page

Step 1: Accessing The Gas Regulator - Thermador PRD364JDGU Instructions Manual

Lp gas conversion
Hide thumbs Also See for PRD364JDGU:

Advertisement

Available languages

Available languages

Appliance
®
Star
Burners
Model
Jet Orifice
Number
THERMADOR PRO GRAND
PRD364JDG*
3 each - 1.15mm
PRD366JGC
5 each - 1.15mm
PRD486JDG*
5 each - 1.15mm
PRD48JDSG*
5 each - 1.15mm
NOTES:
* Model numbers with letter "D" have an Electric
Griddle, which does not require conversion to gas.
Table 2: LP Orifice Conversion Chart
High Altitude:
For safe LP conversion of an appliance for use at higher
elevations, consult the local gas company for their
recommendations for correct orifice sizes and any other
necessary adjustments that will provide proper gas
combustion at high altitudes.
POWERBOOST
TM
Jet Orifice
®
Dual-Fuel Ranges:
1 each - 1.25mm
1 each - 1.25mm
1 each - 1.25mm
1 each - 1.25mm
Step 1: Accessing the Gas
Regulator and Burner Orifices
NOTICE:
After the replacement of each orifice, and before
re-assembly of the burner, perform a brief gas leakage
check of the orifice and associated fittings, per the
"Check for Gas Leaks" section of these instructions.
1. Disconnect all electrical power at the main circuit
breaker or fuse box.
2. Shut off the gas supply to the range by closing the
manual shut-off valve.
3. Remove the cooking grates.
English 3