AUXILIARY RELAY SWITCHES
AUX RELAY switches
AUX RELAY
SWITCH
SETTING
SETTINGS
1
2
3
OFF OFF OFF
Off (no feature
selected)
OFF OFF ON
Open Limit
Switch
OFF ON OFF
Close Limit
Switch
OFF ON ON
Gate Motion
ON OFF OFF Energizes 3 seconds before gate motion and remains energized during gate
Pre-Motion
Delay
ON ON OFF Energizes when AC power or solar power is present. There is approximately
Power
ON OFF ON
Tamper
ON ON ON
Cycle Quantity
Feedback*
CYCLE COUNT
* First, note the current Aux Relay switch positions. To
determine the actual cycles that the gate operator has
run (in thousands), set all three Aux Relay switches to
the ON setting for Aux Relay 1. The Expansion Board's
OPEN, CLOSE, and STOP LEDs will blink out the cycle
count, with OPEN LED blinking 1000's, CLOSE LED blink
10,000's, STOP LED blinking 100,000's, and
simultaneously all three LED's blink 1,000,000's (e.g.
Open blinks 3 times, Close blinks 6 times, and Stop
blinks once. Cycle count is 163,000.). Cycle count
displayed is between 1,000 and 9,999,000 cycles.
After servicing, set Aux Relay switches back to their
appropriate positions. Cycle count cannot be reset or
changed. If under 1,000 cycles the Open, Close, and
Stop LEDs will turn on for 10 seconds, then turn off.

RESET SWITCH

MODELS CSL24V AND CSL24VH
The reset switch is located on the front of the operator and serves several functions.
Toggling the reset switch will stop a moving gate during a normal open/close cycle,
like a stop button. The operator does not need to be reset after doing this. The reset
switch will disable the gate in the present position and will energize the solenoid lock
for two minutes and disable the maglock for two minutes.
MANUAL DISCONNECT
Press the reset switch to RESET/DISCONNECT to allow the gate to be opened and
closed manually. To resume normal operation press the reset switch to NORMAL
OPERATION.
Set the AUX RELAY switches as needed to obtain the desired function:
AUX RELAY 1
Relay always off. Use this Aux Relay setting to conserve
battery power.
Energizes at open limit. Use with SAMS (Sequenced Access Management
System, jointly with barrier gate)
Energizes when not at close limit. Connect "Gate Close/Secure" indicator
(e.g. light).
Energizes when motor is on (gate in motion). Connect "Gate In Motion"
indicator (e.g. warning light or sounder).
motion. Connect "Gate In Motion" indicator (e.g. warning light or sounder).
a 10-12 second delay before relay cutoff, after AC shutdown.
Energizes if gate is manually tampered with by being pushed off of close
limit. Connect alert (e.g. light or sounder).
The OPEN, CLOSE, and STOP LEDs will blink out the cycle count
See below.
FOR CSW AND CSL GATE OPERATORS
Relay always off. Use this Aux Relay setting to conserve battery power.
Energizes when at open limit. Use with SAMS (Sequenced Access
Management System, jointly with barrier gate)
Energizes when not at close limit. Connect "Gate Not Closed/Secure"
Energizes when motor is on (gate in motion). Connect "Gate In Motion"
Energizes when on battery power. There is approximately a 10-12
second delay before relay cutoff, after AC shutdown.
Energizes if gate is manually tampered with by being pushed off of close
1
ADDENDUM
AUX RELAY 2
indicator (e.g. light).
indicator (e.g. warning light or sounder).
Not used.
limit. Connect alert (e.g. light or sounder).
Not used.
SBC
Com
Open
Close
Stop
Com
NORMAL OPERATION
RESET/DISCONNECT
Single
Button
Control
Station
3-Button
Control
Station

Advertisement

loading

Summary of Contents for Chamberlain CSL24V

  • Page 1: Reset Switch

    If under 1,000 cycles the Open, Close, and Stop LEDs will turn on for 10 seconds, then turn off. RESET SWITCH MODELS CSL24V AND CSL24VH The reset switch is located on the front of the operator and serves several functions. NORMAL OPERATION Toggling the reset switch will stop a moving gate during a normal open/close cycle, like a stop button.
  • Page 2 MODELS CSW24V AND CSW24VH MANUAL DISCONNECT Manual Disconnect Handle Press the reset switch to RESET/DISCONNECT. Release the handle on the operator arm to allow the gate to be opened and closed manually. On a dual gate application the handle must be released on both operators. To resume normal function tighten the NORMAL OPERATION handle by pushing it down.
  • Page 3 There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. Model CSL24V is shown for illustration purposes. Wired dual gate applications will have a longer battery standby time than wireless applications.
  • Page 4 The BIPART DELAY is also used in applications where one gate travels a longer distance than the other. To synchronize the closing of the gates, set the LOCK/ BIPART DELAY switch to ON for both operators. ©2011 The Chamberlain Group, Inc. www.liftmaster.com 01-36603B...

This manual is also suitable for:

Csl24vh