Triaxial high amplitude mems shock accelerometer (11 pages)
Summary of Contents for PSB 3503A1160KG
Page 1
Model 3503A1160KG TRIAXIAL HIGH AMPLITUDE MEMS SHOCK ACCELEROMETER Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
Page 2
Service, Repair, and Return Policies and Instructions The information contained in this document supersedes all similar information that may be found elsewhere in this manual. also good practice to recalibrate after Service – Due to the sophisticated exposure to any severe temperature nature of the sensors and associated extreme, shock,...
Page 3
list(s) accompanying the shipment. A complete list of distributors and offices detailed account of the nature of the found www.pcb.com. problem(s) being experienced with the Customers within the United States may equipment should also be included contact their local sales representative inside the package(s) containing any factory customer...
Page 5
Component Name Hazardous Substances Lead Mercury Cadmium Chromium VI Polybrominated Polybrominated (Pb) (Hg) (Cd) Compounds Biphenyls Diphenyl (Cr(VI)) (PBB) Ethers (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
Page 6
3500/3600 Series Piezoresistive Shock Accelerometer Operating Guide Introduction display a slight linear decrease in sensitivity as temperature increases. TZS – Thermal Zero Shift, the change in ZMO due to This Operating Guide contains information that will familiarize the user with the basic operation and installation of temperature.
Page 7
3500/3600 Series Piezoresistive Shock Accelerometer Operating Guide check the mounting torque after each measurement. It’s performed. These are violent events. Because of the critical nature of these and similar test applications, PCB MEMS DC also recommended that a thread locking adhesive be Accelerometers have been designed and manufactured with the applied to any threads, if applicable.
Page 8
3500/3600 Series Piezoresistive Shock Accelerometer Operating Guide the shunt resistor are accurately known. Among other sources immediate dynamic instrumentation needs with a Factory of variability, temperature can change the value of the Representative. resistors, and therefore the Shunt Calibration output. The user should be aware that because the sensors are full bridge transducers, all legs are active and will have temperature coefficients typical of piezoresistive sensors (approximately...
Page 9
Model Number Revision: NR TRIAXIAL HIGH AMPLITUDE MEMS SHOCK ACCELEROMETER ECN #: 46383 3503A1160KG Performance ENGLISH OPTIONAL VERSIONS Sensitivity(± 50 %)(at 10 VDC excitation) 0.003 mV/g 0.0003 mV/(m/s²) Optional versions have identical specifications and accessories as listed for the standard model Sensitivity 0.0003 mV/V/g...
Page 10
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. .465 [11.81] RELEASED TO DRAFTING 46383 .365 [9.27] .100 [2.54] 45°...
Page 11
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. -SEE SHEET ONE- "SERVICE LOOP" TO ALLOW MOTION WITHOUT PULLING CABLE TAPE...