Options/Address Jumpers
The options/address jumpers (see Figure 6-2) enable you to select options and
set a unique SCSI address for your CD-ROM drive. The address is set with the
rear panel SCSI address switches (refer to Figure 1-2 and Table 1-1).
Note
Caution
,
On some older mass storage systems (Models
330D/S
and
660D/S),
the rear panel SCSI address switches are for hard
disk drives only. For this reason, the device in your upgrade
kit is shipped with necessary address jumpers or DIP switches
installed.
If
you do not have a Model
330D/S
or
660D/S
mass
storage system, these device address jumpers or DIP switches
are not needed and can be removed. Connect the address cable
in their place as shown in Figure 6-6.
The options jumpers must be left in the factory-set positions.
These settings are shown in Figure 6-2. Make sure the address
switch on the mass storage system rear panel is set to a unique
SCSI address relative to the other devices on the SCSI bus. The
mass storage system will not function properly if two devices
have the same SCSI address.
CD·ROM Drive Installation
6·3