Electrical
Requirements
Continued
115 volt models with amperes
-
up through 12.0
Receptacle
wiring
Receptacle
wiring should be a minimum of
14 gauge. Use copper wire only. It is the respon-
sibility of the consumer to provide proper and
adequate receptacle wiring, installed by a
qualified electrician. Observe National Electrical
Code and all local governing codes and ordi-
nances.
Electrical
requirements
A 115 volt (103.5 min., 126.5 max.), 60 Hz, AC
only, 15 ampere fused electrical supply is
required (time delay fuse or time delay circuit
breaker required). For models with serial plate
amperes of 7.6 through 12, it is required
that a
separate circuit, serving only this appliance,
be
provided.
Electrical
connection
II
Electrical ground is required on this appliance.
Recommended
grounding
method:
3prong
For your personal safety, this appliance
must be
grounding
grounded. This air conditioner is equipped with a
Plug
%v-
8
!'
power supply cord having a 3-prong grounding
prong. To minimize possible shock hazard, the
cord must be plugged into a mating 3-prong
Grounding
grounding type wall receptacle,
grounded in
prong
4
3prong
accordance with the National Electrical Code and
grounding
type wall
local codes and ordinances.
If a mating wall
receptacle
receptacle is not available,
it is the responsibility
of the customer to have a properly grounded
Power
W$lY
3-prong wall receptacle installed by a qualified
electrician.