Shure UA846Z2 Manual

Frequency manager

Advertisement

Quick Links

IMPORTANT SAFETY INSTRUCTIONS
1. READ these instructions.
2. KEEP these instructions.
3. HEED all warnings.
4. FOLLOW all instructions.
5. DO NOT use this apparatus near water.
6. CLEAN ONLY with dry cloth.
7. DO NOT block any ventilation openings. Allow sufficient distances for
adequate ventilation and install in accordance with the manufacturer's
instructions.
8. DO NOT install near any heat sources such as open flames, radiators,
heat registers, stoves, or other apparatus (including amplifiers) that pro-
duce heat. Do not place any open flame sources on the product.
9. DO NOT defeat the safety purpose of the polarized or grounding type
plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. The
wider blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement
of the obsolete outlet.
10. PROTECT the power cord from being walked on or pinched, particularly
at plugs, convenience receptacles, and the point where they exit from
the apparatus.
11. ONLY USE attachments/accessories specified by the manufacturer.
12. USE only with a cart, stand, tripod, bracket, or table specified by the
manufacturer, or sold with the apparatus. When a cart is used, use caution
when moving the cart/apparatus combination to avoid injury from tip-over.
13. UNPLUG this apparatus during lightning storms or when unused for long
periods of time.
14. REFER all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power
supply cord or plug is damaged, liquid has been spilled or objects have
fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
General Description
The GLX-D Frequency Manager distributes RF signal and DC power for
Shure GLXD4R receivers. The rack-mountable system increases channel
count and reduces the number of required antennas and power supplies.
When connected to the GLX-D Frequency Manager, GLXD4R receivers op-
erate in the most spectrally efficient manner.
Features
Improves the RF performance of connected GLXD4R receivers
Increases channel count with more efficient frequency management
Distributes RF signal and power to six receivers
Cascade ports connect second frequency manager for up to 11 receivers
©2016 Shure Incorporated
15. DO NOT expose the apparatus to dripping and splashing. DO NOT put
objects filled with liquids, such as vases, on the apparatus.
16. The MAINS plug or an appliance coupler shall remain readily operable.
17. The airborne noise of the Apparatus does not exceed 70dB (A).
18. Apparatus with CLASS I construction shall be connected to a MAINS
socket outlet with a protective earthing connection.
19. To reduce the risk of fire or electric shock, do not expose this apparatus
to rain or moisture.
20. Do not attempt to modify this product. Doing so could result in personal
injury and/or product failure.
21. Operate this product within its specified operating temperature range.
Explanation of Symbols
Caution: risk of electric shock
Caution: risk of danger (See note.)
Direct current
Alternating current
On (Supply)
Equipment protected throughout by DOUBLE INSULATION or
REINFORCED INSULATION
Stand-by
Equipment should not be disposed of in the normal waste stream
WARNING: Voltages in this equipment are hazardous to life. No user-ser-
viceable parts inside. Refer all servicing to qualified service personnel. The
safety certifications do not apply when the operating voltage is changed from
the factory setting.
Consolidates antennas and power supplies for simpler setup
Mounts in standard 19 inch equipment racks
Supports remote antenna placement
All-metal construction
Included Components
Rack-mounting hardware
External power supply
(6) threaded DC power cables
(2) Reverse SMA Cable
UA846Z2
Frequency Manager
1/7

Advertisement

Table of Contents
loading

Summary of Contents for Shure UA846Z2

  • Page 1 The GLX-D Frequency Manager distributes RF signal and DC power for • Consolidates antennas and power supplies for simpler setup Shure GLXD4R receivers. The rack-mountable system increases channel • Mounts in standard 19 inch equipment racks count and reduces the number of required antennas and power supplies.
  • Page 2: Optional Accessories And Replacement Parts

    UA846Z2 Frequency Manager Shure Incorporated Optional Accessories and Replacement Parts 15.2 m (50 ft.) Reverse SMA Cable UA850-RSMA Passive Directional Antenna 2.4 GHz PA805Z2-RSMA 30.4 m (100 ft.) Reverse SMA Cable UA8100-RSMA Wall Mount for PA805-RSMA and UA8-2.4GHZ UA505-RSMA Power Supply PS60 1/2 Wave Antenna, 45 deg.
  • Page 3: Hardware Connections

    UA846Z2 Frequency Manager Shure Incorporated ⑨ Cascade RF B Connector Connect to second frequency manager's antenna inputs, or connect a sixth receiver. Note: Do not use other RF outputs to connect to a second frequency manager. ⑩ RF B Connectors Connect to receiver's antenna B input.
  • Page 4: Selecting Frequency Groups

    UA846Z2 Frequency Manager Shure Incorporated UA846Z2 GLX-D FREQUENCY MANAGER 15 V DC Power Cable Reverse SMACable Selecting Frequency Groups The GLX-D Frequency Manager creates a shared group of frequencies for all receivers to use and automatically assigns frequencies to each receiver. If inter- ference occurs, the frequency manager assigns new frequencies without audible dropouts.
  • Page 5: Linking Transmitters And Receivers

    UA846Z2 Frequency Manager Shure Incorporated Channel Count Group Latency Notes (Number of Receivers) 6 typical, 9 maximum 4 ms 9 typical, 11 maximum 7.3 ms Best group if you experience interference. Linking Transmitters and Receivers Tip: Turn on and link one transmitter and receiver pair at a time to prevent 1.
  • Page 6: Receiver Channel Display

    UA846Z2 Frequency Manager Shure Incorporated • Use only low-loss reverse SMA cable to avoid poor RF signal. • Always perform a walk-around test to verify coverage before using a wireless system during a speech or performance. Experiment with anten- ⁃...
  • Page 7: Patent Notice

    Phone: +49-7262-92 49 0 ference, including interference that may cause undesired operation of the Fax: +49-7262-92 49 11 4 device. Email: info@shure.de Patent Notice U.S. patent number 9,019,885. Shure Incorporated 5800 West Touhy Avenue Niles, IL 60714-4608 USA Phone: +1-847-600-2000 Email: info@shure.com...

Table of Contents