SiBE12-818
1.6

Outdoor Units

Connectors
PCB(1)(Main PCB)
1)
2)
3)
4)
5)
6)
7)
8)
9) S51,
10)
11)
12)
13)
14)
15) AC1,
16) HR1,
PCB(2)(Service Monitor PCB)
1) S52,
Note:
Other Designations
PCB(1)(Main PCB)
1)
2)
3) V2, V3,
PCB(2)(Service Monitor PCB)
1)
2)
3)
4)
5)
6)
Printed Circuit Board Connector Wiring Diagram
S10
Connector for terminal strip (indoor-outdoor transmission)
S15
Connector for COOL / HEAT mode lock
S20
Connector for electronic expansion valve coil A port (white)
S21
Connector for electronic expansion valve coil B port (red)
S22
Connector for electronic expansion valve coil C port (blue)
S23
Connector for electronic expansion valve coil D port (yellow)
S24
Connector for electronic expansion valve coil E port (green)
S40
Connector for overload protector
S101
Connector for service monitor PCB
S70
Connector for fan motor
S80
Connector for four way valve coil
S90
Connector for thermistors
(outdoor air, heat exchanger, discharge pipe)
S92
Connector for gas pipe thermistor
S93
Connector for liquid pipe thermistor
AC2
Connector for terminal strip (power supply)
HR2
Connector for reactor
S102
Connector for control PCB
FU1
Fuse
FU2, FU3
Fuse (3.15A)
V5, V9,
Varistor
V100
LED A
Service monitor LED (green)
LED1 - LED5
Service monitor LED (red)
SW1
Forced operation ON/OFF switch
SW3
Wiring error check switch
SW4
Priority room setting switch
SW5
Night quiet mode setting switch
Printed Circuit Board Connector Wiring Diagram