From
10° ± 1° at 2000 rpm
Spark advance variation
Specification
Version 200 : Operation threshold
Version 200 : Reactivation threshold
Spark elimination
Specification
Operation threshold
Reactivation threshold
Spark elimination
MAIN - 40
V
200
ERSION
First threshold : 9900 ±50 Second threshold : 10100 ±50
First threshold : 9800 ±50 Second threshold: 10000 ±50
First threshold : 1 spark on 7 Second threshold : 2 sparks on 3
VERSION 125
First threshold : 10700 ±50
Second threshold : 11000 ±50
First threshold : 10600±50
Second threshold : 10900±50
First threshold : 1 spark on 7
Second threshold : 2 sparks on 3
Runner 125 - 200
Desc./Quantity
Desc./Quantity