Display Of Standby/Timer Light Flash Count; Stopping The Standby/Timer Flash; Self-Diagnostic Screen Display; To Bring Up Screen Test - Sony KV-EX29M93 Service Manual

Trinitron color tv
Hide thumbs Also See for KV-EX29M93:
Table of Contents

Advertisement

KV-EX29M39/EX29M87/EX34M97
KV-EX29M93/EX29M65

2. DISPLAY OF STANDBY/TIMER LIGHT FLASH COUNT

2 times
3 times
Lamp ON 0.3 sec.
Lamp OFF 0.3 sec.
4 times
5 times
6 times

3. STOPPING THE STANDBY/TIMER FLASH

Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER lamp
from flashing.

4. SELF-DIAGNOSTIC SCREEN DISPLAY

For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes out" that cannot be confirmed, it
is possible to bring up past occurances of failure for confirmation on the screen:

[To Bring Up Screen Test]

In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
[Screen display] / channel [5] / Sound volume [-] / Power ON
Self-Diagnosis screen display
SELF DIAGNOSTIC
002 : 000
003 : 000
004 : 000
005 : 001
006 : 002
101 : 000
RM-963
RM-964
Lamp OFF 3 sec.
Numeral "0" means that no fault has been detected.
Numeral "1" means a fault has been detected.
Numeral "2" means two faults have been detected.
Diagnostic Item
+B overcurrent
+B overvoltage
V deflection stop
White balance failure
Horizontal Deflection Failure
* One flash count is not used for self-diagnostic.
˘
Note that this differs from entering the service mode (mode volume [+]).
– 6 –
Flash Count*
2 times
3 times
4 times
5 times
6 times
STANDBY/SLEEP lamp