Error Codes & Possible Causes - Hotpoint WML540GUK.R Service Information

Table of Contents

Advertisement

Indesit
Company
ERROR CODES & POSSIBLE CAUSES
When an error occurs the following LEDs will indicate a fault, along with flashing option LEDs.
CONTROLS - LED MODEL
FAULT
LED COMBINATION
5
4
F01
Off
Off
F02
Off
Off
F03
Off
Off
F04
Off
Off
F05
Off
Off
F06
Off
Off
F07
Off
Off
F08
Off
On
F09
Off
On
F10
Off
On
F11
Off
On
F12
Off
On
F17
On
Off
F18
On
Off
Service Manual UK
Option Buttons
3
2
1
Off
Off
On
Off
On
Off
Off
On
On
On
Off
Off
On
Off
On
On
On
Off
On
On
On
Off
Off
Off
Off
Off
On
Off
On
Off
Off
On
On
On
Off
Off
Off
Off
On
Off
On
Off
Possible Causes
Motor triac short circuit: Check motor
F01
and module connections
Motor jammed / tacho detached: Check
F02
motor and module connections
NTC short/open circuit: Check thermistor
F03
and module connections
Pressure switch jammed on empty:
F04
Check switch and module
Pressure switch jammed on full or pump
F05
blocked: Check pump and switch
F06
N/A
Heater relay stuck: Check heater and
F07
module connections
Heater relay stuck: Check pressure
F08
switch, heater and module connections
F09
Setup error: Check Eeprom
Pressure switch not sensing: Check
F10
switch and module connections
Pump cannot be activated: Check pump,
F11
connections and wiring
No communication between cards:
F12
Check module connections
Door lock error: Check door, door lock
F17
and module connections
Communication error (3 phase motor):
F18
Replace power board
21 of 33
LED 5
LED 4
LED 3
LED 2
LED 1
English

Advertisement

Table of Contents
loading

Table of Contents