Program Unit Capacity/Size Mode - Lennox SL280UH090V36B Installation Instructions Manual

Sl280uhv series
Hide thumbs Also See for SL280UH090V36B:
Table of Contents

Advertisement

Integrated Control Diagnostic Modes
Code
Diagnostic Codes/Status of Equipment
E406
LSOM - Compressor open start circuit.
E407
LSOM - Compressor open run circuit.
E408
LSOM - Compressor contactor is welded.
E409
LSOM - Compressor low voltage.
Program Unit Capacity / Size Mode
Power-Up - Number displayed represents by integrated control unit size code (furnace model
and capacity). If three horizontal bars are displayed followed by continuous E203, furnace
control does not recognize unit size code. Configure per the following:
To enter Program Unit
Capacity/Size:
and hold button next to
7-segment LED display
until solid "P" symbol
appears.
button.
IMPORTANT: Field replacement controls may
need to be manually configured to validate
furnace unit size code.
Solid
blinking
7-Segment LED
Push and hold button. Integrated control will
display unit size code number for each
furnace model for three seconds.
Yes
push
_
Release
P
starts
P
on
FINISHED
Action Required to Clear and Recover
Required amount of current is not passing through Start cur-
rent transformer. Clears the error after current is sensed in
START sensor, or after power reset.
Required amount of current is not passing through Run current
transformer. Clears the error after current is sensed in RUN
sensor, or 1 normal compressor run cycle, or after power reset.
Compressor runs continuously. Clears the error after 1 normal
compressor run cycle or after power reset.
Secondary voltage is below 18VAC. After 10 minutes, oper-
ation is discontinued. Clears the code after voltage is higher
than 20 VAC for 2 seconds or after power reset.
Furnace control in IDLE mode
No heating, cooling or indoor fan
operation)
UNIT SIZE
CODE
FURNACE MODEL
A
SL280UH070V36A
b
SL280UH090V36B
C
SL280UH090V48B
d
SL280UH090V60C
E
SL280UH110V60C
F
SL280UH135V60D
When the correct unit size code is displayed, release
button. Selected code will flash for 10-second period.
During that period, press and hold push button for 5
seconds. Integrated control will store code in
memory and will automatically exit Program Unit
Capacity/Size Mode and reset. (If second period
expires or push button is held less than five seconds,
control
Capacity/Size Mode and go into IDLE mode without
storing unit size code. If this happens, programming
function must be repeated).
Verify that the selected unit size code is correct
and stored in non-volatile memory by cycling
the 24 volt power to the furnace control. (At 24
volt power-up of the furnace control, the
7-segment LED will display a unit size code. If
three horizontal bars display, board does not
recognize unit size code. Programming
function must be repeated)
Page 55
− −
No
Turn room thermostat to OFF
UNIT SIZE
CODE
FURNACE MODEL
H
SL280DF070V36A
J
SL280DF090V48B
L
SL280DF090V60C
n
SL280DF110V60C
will
automatically
exit
Program
− −