8
ELECTRICAL CONNECTIONS
3-WIRE CONNECTION WITH A
POWER SUPPLY CORD
WARNING
• The middle (neutral or ground) wire of a 3 wire
power cord or a 3 wire conduit must be connected
to the middle post of the main terminal block. The
remaining two wires of the power cord or conduit
must be connected to the outside posts of the main
terminal connection block.
− Failure to do so can result in electrical shock,
severe personal injury or death.
Install the power cord as follows:
For power cord installations, hook the strain relief over the
power cord hole (1
3
/
") located below the rear of lower
8
oven. Insert the power cord through the strain relief and
tighten it. (Refer to Figure 7.)
DO NOT install the power cord without a strain relief.
1. Remove the lower 3 screws from the terminal block and
retain them. (Refer to Figure 8.)
2. Insert the 3 screws through each power cord terminal ring
and into the lower terminals of the terminal block. Make
sure that the center wire (white/neutral) is connected to
the center lower position of the terminal block.
3. Tighten 3 screws securely into the terminal block.
Do not remove the ground strap connections.
4. Go to page 11.
Cord strain relief
Separate strain relief
before installation
Assemble the strain relief
to the 1
3
/
" opening in
8
conduit connection plate
FIGURE 7
3-wire connection
Black
Conduit
connection plate
FIGURE 8
Conduit
connection
plate
Power cord
White
Red
Terminal
block