Philips 200P4VG/00 Service Manual page 16

20" tft lcd colour monitor
Table of Contents

Advertisement

Uh3 200P4
16
Go to cover page
2.9 Adjust the R, G, B Sub-Gain on factory mode for the screen
center, the 1931 CIE chromaticity (X, Y) co-ordinates shall be
as follows.
9300°K
Use Minolta CA-110 for colour coordinates and luminance check.
Luminance is > 200 Nits in the center of the screen when
brightness at 100% and contrast set to 100%.
x(center)
y(center)
Ynits
Alignment hits:
R for x value , G for y value, B and Sub-brightness for Y value on the
Colour analyzer.
2.10 Exit factory mode and User mode, then do DC on/off and AC on/of
to reset CPU.
Factory Preset (B):
After finished all the adjustment, set:
OSD Default Setting:
Brightness: 100%
Contrast: 50%
Adjust size: Full screen
Language: English
Colour: 6500K for IMAGE MANAGEMENT
OSD position: middle of the LCD screen
Input Selection: Default as Analogue (D-sub)
PIP size: Medium
PIP position: up right corner
PIP audio source: PC Audio
PIP video source: CVBS
Volume: 50%
Display Adjustment
6500°K
sRGB
0.313 ± 0.020
0.329 ± 0.020
200 ± 10 Nit

Advertisement

Table of Contents
loading

Table of Contents