Alignments
8. Alignments
General: the Service Default Mode (SDM) and Service
Alignment Mode (SAM) are described in chapter 5 'Service
modes, faultfinding and repair tips'.
8.1
Alignment conditions
All electrical adjustments should be performed under the
following conditions:
Supply voltage : 220 - 240 VAC (+/- 10 %)
Warm-up time: 10 minutes
The voltages and oscillograms are measured in relation to
the tuner earth.
Test probe: Ri > 10MΩ Ci < 2,5 pF.
8.1.1
Selection of the SAM-menu
By transmitting the "ALIGN" command with the RC7150
Dealer Service Tool, followed by password "3140" and <
OK > button.
Standard RC sequence 062596 (within OSD time-out)
OSD
By shorting test-point M28 and M29 on the AV Control
panel on the monitor while switching on the set.
8.2
Adjustments on the D-box
8.2.1

Electrical Alignments

Pre-conditioner +5Vstby (PR3)
Connect a voltmeter to capacitor C2510 (PR2). With the aid of
R3504 adjust the voltage to 5.2 V +/- 50 mV.
VsVa supply (FD)
Va-supply (Addressing of the PDP - FD1)
De-activated the PDP.
Connect a voltmeter to capacitor C2120 (FD1). With the aid of
R3126 adjust the voltage to 55 V +/- 0.5 V.
Vs-supply (Sustain pulses - FD2)
De-activated the PDP.
Connect a voltmeter to capacitor C2020 (FD2). With the aid of
R3026 adjust the voltage to 165 V +/- 0.5 V.
8.2.2
Software Alignments
White point
Select the item "PDP test pattern" of the Service Alignment
menu and set it to "ON.
Select item " White point" of the Service Alignment menu.
Enter the "white point" menu and adjust the value of one of
the 4 submenu if necessary. Only the selected menu-item
including its value remain on the screen when selected.
The value has to changed within 5 seconds otherwise the
main menu reappears again.
The 4 sub menu-items of the White point menu:
"RED"
"GREEN"
"BLUE"
"COLOUR TEMPERATURE"
Leave the sub-menu by pressing "cursor up", "cursor
down", "OK" or the "MenuOnOff" button and return to the
main menu.
Select the item "PDP test pattern" of the Service Alignment
menu and set it to "OFF.