Detailed Specifications - Infinity TSS-Sub800 Service Manual

Tss-800 system
Table of Contents

Advertisement

TSS-Sub800
TSS-Sub800 100W Powered Sub/ Plate Amp
LINE VOLTAGE
US 120VAC/60Hz
Europe 220-240VAC, 50-60Hz
Parameter
Specification
Amp Section
Type (Class AB, D, other)
Type (Class AB, D, other)
Load Impedance (speaker)
Rated Output Power
THD@ Rated Power
THD @ 1 Watt
DC Offset
Damping factor
Input Sensitivity
Input Frequency
Line Input (L&R)
LFE Input
Signal to Noise
SNR-A-Weighted
SNR-unweighted
SNR @ 1W-unweighted
Residual Noise Floor
Residual Noise Floor
Input Impedance
Line input L&R , LFE
Filters
Low Pass (fixed or variable)
Slope & Q
Subsonic filter (HPF)
Slope & Q
Limiter (yes/no)
THD at Max. Output Power
Features
LFE Input
Phase Switch (yes/no)
Volume pot Taper (lin/log)
ATO
Input Configuration
Line In (L,R)
Line level in LFE
Signal Sensing (ATO)
Auto-Turn-On (yes/no)
ATO Input Frequency
ATO Level
ATO Turn-on time
Auto Mute/ Turn-OFF Time
Power on Delay time
Transients/Pops
ATO Transient
Turn-on Transient
Turn-off Transient
Efficiency
Stand-by Input Power
Power Cons.@rated power
Yes/No
Hi/Lo Line
Unit
Yes
108-132
Vrms
Yes
220-230
Vrms
Unit
QA Test Limits
AB AB
n/a
G G
n/a
4 Ohms
n/a
100 Watts
95
0.5 %
1
0.1 %
0.3
10 mV-DC
50
100
>100 DF
50 Hz
50
±2dB
15.62 mVrms
10.36 mVrms
±2dB
85
100 dBA
80 dBr
80
60 dBr
60
2.5
1.5 mVrms
1
2
mVrms(max)
>10 K ohms
n/a
4th order
--
±2dB
dB/Octave
n/a
±2dB
2nd order fix Hz
dB/Octave
n/a
YES
--
Functional
Functional
1
%
YES
Functional
Functional
YES
--
LOG
--
Functional
YES
Functional
L ,R
--
Functional
LFE
Functional
YES
--
Functional
50 Hz
Functional
2 mV
Functional
5 ms
Functional
10 minutes
Functional
3 sec.
Functional
10
5 mV-peak
50 mV-peak
100
50 mV-peak
100
14 Watts
18
195 Watts
210
Notes
Normal Operation
Normal Operation
Conditions
120V Model
230V Model
Nominal
Single input driven
22K filter
22K filter
@ Speaker Output
50Hz-4 Ohms load
Nominal Freq.
To 1 Watt
To 1 Watt
rel. to rated power
rel. to rated power
rel. to 1W Output
Volume @max, using RMS reading
DMM/VOM (or A/P)
Volume @max, w/ A/P Swept Bandpass
Measurement (Line freq.+ harmonics)
Nominal
2nd order variable 50-150Hz + 2nd order
fix
@
p
driven
Amp connected and AC on, then input
signal applied
T before muting, after signal is removed Auto turn of time (T) must be 5 > T <15
AC Power Applied
@ Speaker Outputs
@ Speaker Outputs
@ Speaker Outputs
@ nom. line voltage
@ nom. line voltage
3
Notes
External heatsink required
External heatsink required
Measured at amplifier board speaker output
terminals, Output power 90 Watts.
Single input driven, AP Zo=600 Ohms
LFE input driven only, AP Zo=600 Ohms
A-Weighting filter
22K filter
22K filter
RCA inputs (L&R)
RCA single input
AC Line cycled from OFF to ON
AC Line cycled from ON to OFF
Maximum allowable input power under
nominal Input voltage and frequency, HOT
or COLD operation.
100 Watts @ 4 Ohms