Boiler Installation; Boiler Size - Baxi LUNA3COMFORT Installers And Users Instructions

High efficiency wall-mounted gas-fired boilers
Table of Contents

Advertisement

Decide upon the boiler location, then tape the template on the wall. Connect the pipework to the gas and water inlets
prearranged on the template lower bar. We suggest you fit two G3/4 stop cocks (available on demand) on the central
heating system flow and return pipework; the cocks will allow to carry out important operations on the system without
draining it completely. If you are either installing the boiler on a pre-existent system or substituting it, we suggest you also
fit settling tank on the system return pipework and under the boiler to collect the deposits and scaling which may remain
and be circulated in the system after the purge.
When the boiler is fixed on the template connect the flue and air ducts (fittings supplied by the manufacturer) according
to the instructions given in the following sections.
When installing the 240 i - 1. 240 i model (boiler with natural draught), make the connection to the flue using a metal pipe
which will provide resistance over time to the normal mechanical stresses, heat and the effects of the combustion products
and any condensation they form.
1.240 i - 1.240 Fi - 1.310 Fi
: G3/4 heating flow / return
: G1/2-G3/4 domestic hot water inlet / outlet
: G3/4 gas inlet to the boiler
0512_0503/CG1769
Figure 5
240 i - 1.240 i
Figure 6

13. BOILER INSTALLATION

CG_2121 / 0904_0706

14. BOILER SIZE

15
240 Fi - 240 i - 310 Fi
: G3/4 heating flow / return
: G1/2 domestic hot water inlet / outlet
: G3/4 gas inlet to the boiler
240 Fi - 310 Fi - 1.240 Fi - 1.310 Fi
0512_0505/CG1769
925.220.4 - EN