Capacity Correction Table By Refrigerant Piping Length; Cooling Capacity Correction; Maximum Refrigerant Piping Length & Maximum Height Difference; Msy-Ge-Na2-1 - Mitsubishi Electric MSY-GE09NA-8 Engineering Manual

M-series msy/muy-ge-na2 cooling only wall-mount air system
Hide thumbs Also See for MSY-GE09NA-8:
Table of Contents

Advertisement

3-9. CAPACITY CORRECTION TABLE BY REFRIGERANT PIPING LENGTH

(1) Cooling capacity correction

MUY-GE09NA2
MUY-GE12NA2
MUY-GE15NA2
MUY-GE18NA-1
MUY-GE24NA
(2) Maximum refrigerant piping length & maximum height difference
Model
MUY-GE09NA2
MUY-GE12NA2
MUY-GE15NA2
MUY-GE18NA-1
MUY-GE24NA
Indoor
unit
Max. Height
difference
Due to continuing improvement, above specification may be subject to change without notice.
MSY-GE-NA2-30
M-Series - MSY/MUY-GE-NA2 Wall-Mount Systems (August 2014)
Refrigerant piping length (one way: ft.)
25 (std.)
1.0
1.0
Refrigerant piping: ft
Additional
Additional
piping
piping
Max. length
Max. height
A
B
65
40
65
40
100
50
100
50
Additional Piping
Max. length
A
B
40
65
0.954
0.878
0.954
0.878
Piping size: in.
Gas
Minimum
Outside
Wall
diameter
thickness
0.0315
3/8
0.0315
1/2
0.0315
1/2
0.0315
5/8
Outdoor unit
100
-
0.771
Liquid
Minimum
Outside
Wall
diameter
thickness
0.0315
1/4
0.0315
1/4
0.0315
3/8
0.0315
3/8
© 2014 Mitsubishi Electric US, Inc.