Major Electrical Components
Starter switch
The diesel-engine turck, which uses a disributor type injection pump, is provided with an engine automatic sop
mechanism of the fuel cut system by the starter switch.
The gasoline-engine truck is also provided with an engine automatic stop mechanism of the fuel cut system.
Starter switch (with Anti-Restart Lock)
This switch has a built-in anti-restart lock, so the key cannot be turned from
the engine is running. This prevents the engine from troubles on starting or starter breakage caused by casual re-
starting while the engine is running. The gasoline- and diesel-engine models use the same starter switch. In the
diesel-engine models,
(ON) position of the switch is for energizing the glow plugs.
(OFF)
Connection Table
Gasoline-engine truck (12 V)
Key position
OFF
ON (when driving)
START (when starting engine)
Diesel-engine truck (24 V)
Key position
OFF
ON (when preheating) (when driving)
START (when starting engine)
(ON)
(START)
Terminal
B1, B2
Connected to
Battery,
alternator,
fuse box
Terminal
B1, B2
Connected to
Battery,
alternator,
fuse box
relay (glow plug)
(ON) to
G1
G2
G1
G2
3-5
ELECTRICAL SYSTEM
(START) position while
G1
M
B2
G2
B1
S
M
Fuse box
FNR lever
M
Fuse box,
Neutral switch
engine stop,
(starter),
control timer
glow timer
208540
S
S