Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Installation and Configuration WARNING: Before performing the following procedure, review the safety instructions that came with the system. Unpacking the System Unpack your system and identify each item. Installing the Rails and System in a Rack CAUTION: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient.
Page 6
Connecting the Power Cable(s) Ensure that the power switch is in the OFF postion before connecting the power cables. Connect the system’s power cable(s) to the system. Securing the Power Cable(s) Bend the system power cable(s) as shown in the illustration and secure the cable(s) firmly to the bracket using the provided strap.
Page 7
Turning On the System Press the power switch to the ON position. The power indicators should light. NOTE: Ensure that the storage enclosure is connected to the server and the mode switch set to split or unified mode before turning on the system. Installing the Optional Bezel Install the bezel (optional).
NOTE: Always check for updates on support.dell.com/manuals and read the updates first because they often supersede information in other documents. NOM Information (Mexico Only) The following information is provided on the device described...
Technical Specifications Drives SAS hard drives Up to 12 3.5-inch SAS hot-swappable hard drives (3.0 Gbps and 6.0 Gbps) Enclosure Management Modules (EMMs) EMMs One or two hot-swappable modules with temperature sensors and an audio alarm Connectivity Configurations Support for either of the following configurations: •...
Page 10
Redundant Array of Independent Disks (RAID) Controller Host-based RAID support using PowerEdge™ RAID controller H800 Management RAID management using Dell OpenManage™ Server Administrator 6.2 or later. Back-Plane Board Connectors • 12 SAS hard-drive connectors • Two power supply/cooling fan module connectors •...
Page 11
LED Indicators (continued) Three two-color LED status indicators, one each for the two EMM SAS ports and one for the EMM status Power supply/cooling fan Three LED status indicators for power supply status, power supply/fan fault, and AC status Switch System identification button Located on the front control panel.
Page 12
28.39 kg (62.6 lb) Weight (empty) 8.84 kg (19.5 lb) Environmental NOTE: For additional information about environmental measurements for specific system configurations, see www.dell.com/environmental_datasheets. Temperature Operating 10° to 35°C (50° to 95°F) with a maximum temperature gradation of 10°C per hour NOTE:...
Page 13
Environmental (continued) Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms Altitude Operating –16 to 3048 m (–50 to 10,000 ft) NOTE: For altitudes above 2950 feet, the maximum operating temperature...
Page 22
(Redundant Array of Independent Disks RAID) RAID PowerEdge™ RAID H800 RAID Dell OpenManage™ Server Administrator 6.2 • 12 个 SAS 硬盘驱动器连接器 • 两个电源设备 / 冷却风扇模块连接器 • 两组 EMM 连接器 • 一个用于前面 LED 的控制面板连接器和 存储设备模式开关 • 一个 SAS IN 连接器,用于连接主机 • 一个 SAS OUT 连接器,用于扩展到附加...
Page 23
功率 600 W 电压 240 VAC 8.6 A 4.3 A 散热 188 W 最大涌入电流 55 A +5 V 1.6 A 12 V 1.6 A +12 V 11 W +12 V 100 W +5 V 8.68 3.41 44.63 17.57 60.20 23.70 28.39 62.6 8.84...
Pemasangan dan Konfigurasi PERINGATAN: Sebelum menjalankan prosedur berikut, pelajari instruksi keselamatan yang disertakan dengan sistem. Mengeluarkan Sistem Keluarkan sistem Anda dan kenali setiap komponen. Memasang Rel dan Sistem dalam Rak PERHATIAN: Jika dipasang di rak multi-unit atau unit rak tertutup, suhu pengoperasian sekitar di area sekitar rak dapat lebih besar daripada suhu ruang.
Page 28
Menyambungkan Kabel Daya Pastikan bahwa switch daya dalam posisi OFF sebelum menyambungkan kabel daya. Sambungkan kabel daya sistem ke sistem. Mengencangkan Kabel Daya Tekuk kabel daya sistem seperti terlihat pada gambar dan kencangkan kabel dengan benar pada braket menggunakan tali yang disediakan. Sambungkan ujung lain kabel daya ke outlet listrik dengan koneksi ground atau sumber daya terpisah seperti catu daya bebas gangguan (uninterrupted power supply/UPS) atau unit distribusi daya (power distribution unit/PDU).
Page 29
Mengaktifkan Sistem Tekan switch daya ke posisi ON. Indikator daya harus menyala. CATATAN: Pastikan bahwa ruang penyimpanan tersambung ke server dan switch mode diatur ke mode terbagi atau tergabung sebelum mengaktifkan sistem. Memasang Bezel Opsional Pasang bezel (opsional). Memulai Pengaktifan dengan Sistem Anda...
Anda beli dengan sistem Anda. CATATAN: Selalu periksa update di situs support.dell.com/manuals dan baca update terlebih dahulu karena biasanya update tersebut menggantikan informasi dalam dokumen. Informasi NOM (Hanya Meksiko)
Spesifikasi Teknis Drive Hard drive SAS Hingga 12 hard drive SAS 3,5-inci yang dapat dilepas/diganti tanpa mematikan sistem (3,0 Gbps dan 6,0 Gbps) Modul Manajemen Penyimpanan (EMM) Satu atau dua modul yang dapat dilepas/diganti tanpa mematikan sistem dengan sensor suhu dan alarm audio Konektivitas Konfigurasi Mendukung salah satu dari konfigurasi...
Page 32
Rangkaian Redundan dari Disk Independen (Redundant Array of Independent Disks/RAID) Kontroler Dukungan RAID berdasar Host menggunakan kontroler PowerEdge™ RAID H800 Manajemen Manajemen RAID menggunakan Administrator Server Dell OpenManage™ versi 6.2 atau setelahnya Papan Back-Plane Konektor • Konektor hard drive 12 SAS • Dua konektor catu daya/modul kipas pendingin •...
Page 33
Indikator LED (Lanjutan) Tiga indikator status LED dua warna, masing-masing satu indikator untuk dua port EMM SAS dan satu indikator untuk status EMM Catu daya/kipas pendingin Tiga indikator status LED untuk status catu daya, gangguan catu daya/kipas, dan status AC Switch Tombol identifikasi sistem Terletak di panel kontrol depan.
Page 34
28,39 kg (62,6 lb) Berat (kosong) 8,84 kg (19,5 lb) Lingkungan CATATAN: Untuk informasi tambahan mengenai pengukuran lingkungan untuk konfigurasi sistem spesifik, lihat www.dell.com/environmental_datasheets. Suhu Pengoperasian 10° hingga 35°C (50° hingga 95°F) dengan gradasi suhu maksimal dari 10°C per jam CATATAN: Untuk ketinggian di atas 2950 kaki, suhu pengoperasian maksimal menurun 1ºF/550...
Page 35
Lingkungan (Lanjutan) Getaran maksimal Pengoperasian Satu pulsasi guncangan pada sumbu z positif (satu pulsasi pada setiap sisi sistem) dari 31 G untuk 2,6 ms dalam arah pengoperasian Penyimpanan Enam pulsasi guncangan yang dilakukan berurutan pada sumbu x, y, dan z positif dan negatif (satu pulsasi di setiap sisi sistem) dari 71 G selama hingga 2 ms Ketinggian...
Page 44
RAID Redundant Array of Independent Disks PowerEdge™ RAID H800 RAID Dell OpenManage™ Server Administrator 6.2 RAID ハードディスクドライブコネクタ 個 • SAS 電源装置 冷却ファンモジュールのコネクタ • 個 コネクタ 組 • EMM 前面 とエンクロージャモードスイッチ用 • のコントロールパネルコネクタ 個 ホストへの接続用 コネクタ 個 • SAS IN 追加エンクロージャ用...
Page 45
EMM SAS ワット数 600 W 電圧 240 VAC 8.6 A 4.3 A 熱消費 188 W 最大流入電流 55 A 1.16 A +5 V 1.6 A +12 V 11 W +12 V 100 W +12 V 1 W +5 V...
Page 46
8.68 cm 44.63 cm 60.20 cm 28.39 kg 8.84 kg メモ www.dell.com/environmental_datasheets 動作時 10° C 35° C メモ 2950 1 ° F 保管時 20° C – 40 65° C 動作時 10 % 80 % 保管時 95 % 動作時 200 Hz 0.25 G...
Page 47
動作時 –16 3,048 m メモ 2950 1° F 保管時 –16 10,600 m クラス ISA-S71.04-1985...
설치 및 구성 경고 : 시스템 포장 풀기 시스템 포장을 풀고 각 항목을 확인합니다 . 레일 및 시스템을 랙에 설치 주의 : (Tma) " " 안전 지침 및 시스템과 함께 제공되는 랙 설치 지침에 따라 레일을 조립하 고 시스템을 랙에 설치합니다 . 시스템...
Page 52
전원 케이블 연결 전원 케이블을 연결하기 전에 전원 스위치가 꺼짐 (OFF) 위치에 있는지 확인하십시오 . 시스템의 전원 케이블을 시스템에 연결합니다 . 전원 케이블 고정 시스템 전원 케이블을 그림에 표시된 대로 구부리고 제공된 스트랩을 사용 하여 브래킷에 케이블을 단단히 고정시킵니다 . 전원...
Page 53
시스템 켜기 전원 스위치를 켜짐 (ON) 위치로 누릅니다 . 그러면 전원 표시등이 켜집니 다 . 주 : 시스템을 켜기 전에 저장장치 인클로저가 서버에 연결되어 있고 모드 스 위치가 분할 또는 단일 모드로 설정되어 있는지 확인하십시오 . 베젤 ( 선택 사양 ) 설치 베젤...
• 하드웨어 소유자 매뉴얼에서는 시스템 기능에 대한 정보를 제공하고 시스템 문제 해결 방법 및 시스템 구성요소 설치 또는 교체 방법을 설명 합니다 . 이 문서는 support.dell.com/manuals 에서 온라인으로도 제공 됩니다 . • 운영 체제, 시스템 관리 소프트웨어, 시스템 업데이트 및 시스템과 함께...
Page 55
기술 사양 드라이브 (3.0 Gbps 6.0 Gbps) 인클로저 관리 모듈 (EMMs) 연결 기능 • 인클로저 당 12개의 하드 드라이브에 직접 연결이 가능한 단일 모드 . – 컨트롤러 포트 당 총 48개의 하드 드라이 브와 컨트롤러 당 96 개의 하드 드라이브 를...
Page 56
독립 디스크 중복 배열 (RAID). PowerEdge™ RAID H800 RAID Dell OpenManage™ Server Administrator 6.2 RAID 후면 패널 보드 • SAS 하드 드라이브 커넥터 12 개 • 전원 공급 장치 / 냉각 팬 모듈 커넥터 2 개 • EMM 커넥터 2 세트...
Page 57
스위치 전원 공급 장치 와트 600 W 전압 100–240 VAC (8.6 A–4.3 A) 열 손실 188 W 최대 유입 전류 10 ms 55 A 사용 가능한 하드 드라이브 전원 ( 슬롯당 ) +5 V 1.16 A +12 V 1.6 A EMM 전원...
Page 58
환경 주 : 특정 시스템 구성을 위한 환경 측정에 대한 자세한 정보는 www.dell.com/environmental_datasheets 를 참조하십시오 . 작동 10° ~ 35°C (50° ~ 95°F), 10°C 주 : 2,950 피트 이상의 고도에서 최대 작동 온도는 1°F/550 ft 로 감소됩니다 . 보관 –40°~65°C (–40°~149°F), 20°C...
Page 60
Printed in Malaysia. Dicetak di Malaysia. w w w. d e l l . c o m | s u p p o r t . d e l l . c o m...
Page 62
Printed in China. Dicetak di China. Printed on Recycled Paper. w w w. d e l l . c o m | s u p p o r t . d e l l . c o m...