Command lists
Command
Command
code
83
Perform calibration check
700 ... 899
HMI display switching
701
Increased resolution
705
Display current tare weight
710
Activate standard display
711
G/N display
712
N display
713
G display
714
N process value
715
B process value
871
Show serial number
875
Display FW version
1000 ...
Basic functions for weighing commands
1001
Set to zero
1011
Tare
1012
Delete tare
1013
Tare specification valid
1016
S7 tare specification valid
The following commands can be triggered in the scale data block SCALE_DB in the area
CMD1 to CMD3:
92
Description
The command calculates the theoretical digital val-
ues in relation to the calibration weights using the
load cell parameters from data record 10 and the
adjustment weights 0, 1 and 2 from data record 3.
These theoretical digits are output in data record 4.
The function can be used to carry out a plausibility
check for the calibration digits in data record 3
which were determined when calibrated using
standard weights.
Activate increased resolution on main display (x 10)
Display current tare weight on main display
Activate standard display gross/net
Display gross/net weight on main display
Display net process weight on main display
Display gross process weight on main display
The serial number of the module is displayed
Show firmware version in current display
Set to zero
Tare
Delete current tare weight
Activate specification of tare weight
Activate specification of S7 tare weight
Service
SIWAREX WP321
Manual, 07/2014, A5E33715669A-02
x
x
x
x
x
x
x
x
x
x
x

Advertisement