Section 3: Operation

Site Prep Verification

It is important that the generator is installed in such a way
that the airflow into and out of the generator is not
impeded. Verify that all shrubs or tall grasses have been
removed within 3 ft (0.91 m) of the intake and discharge
louvers on the sides of the enclosure. It is also important
that the generator is not subject to water intrusion. Verify
that all potential sources such as water sprinklers, roof
run-off, rain gutter down spouts and sump pump
discharges are directed away from the generator
enclosure.
Automatic start-up. Disconnect utility power and
render unit inoperable before working on unit.
Failure to do so will result in death or serious injury.
Turn the generator OFF before performing maintenance.
Remove 7.5 Amp fuse, T1& T2 battery charge fuse, and
disconnect battery cables to prevent accidental start up.
Disconnect
the
NEGATIVE
disconnect the POSITIVE (+) cable. When connecting
the cables, connect the POSITIVE cable first, the
NEGATIVE cable last.
WARNING

Controller Lid

To open or close the controller lid:
1. See view "A" in
Figure
open. Lid will lock in place when raised.
2. See view "B" in
Figure
out sightly to unlock, then lower to close.
A
Figure 3-1. Open and Close Controller Lid
Owner's Manual for 5.6 kVA PowerPact™
DANGER
(–)
cable
first,
3-1. Lift lid from bottom to
3-1. Pull raised lid up and
B
C
NOTE: Local codes may require this compartment to be
locked. A hasp is provided so the owner/operator can
secure the compartment with a padlock (C in
Check local codes for side compartment locking
requirements.
NOTE: All appropriate panels must be in place during
any operation of the generator. This includes operation
by
a
troubleshooting procedures.

Circuit Breaker

The Main Line Circuit Breaker (MLCB) is located under
the Controller Lid. Open the Controller Lid to access the
circuit breaker (A in
(000191)
then
Figure 3-2. Control Panel and Circuit Breaker
(000182)
001038
servicing
technician
Figure
3-2).
A
Figure
3-1).
while
conducting
B
001127
9