Judgment
∙ Detect according to temperature detected with the EVI-In pipe temperature thermistor.
Method
Cause of
∙ EVI-In temperature sensor is defective. (open/short)
problem
1. Cause of problem
sensor connector (CN44) connected
Separate the connector of the Outdoor EVI In
Temperature sensor from the PBA and measure
the resistance value between the 2 terminals.
Is the resistor value matching with
Restart operation after replace the PBA
Samsung Electronics
Defrost
Timer
Fan
Filter/MPI
×
Outdoor EVI IN
to PBA?
Yes
"NOTE1" table?
Yes
Cassette (4/Mini4 Way)
Operation
Defrost
×
No
Restart operation after connecting
the connector to PBA
Resistance value measure part
EVI-IN
CN44 (3, 4)
No
Replace this part as it is the defective of the
Outdoor EVI In Temperature sensor itself.
Wall-mounted (NeoForte)
Timer
Filter Operation
NOTE1
Temperature(°C)
Resistance(KΩ)
70
2.2
60
3.0
50
4.2
40
5.8
30
8.3
20
12.1
10
18.0
0
27.3
-10
43.0