2011.06.24
INDOOR UNIT
COMPACT WALL MOUNTED
ASYG07LUCA
ASYG09LUCA
ASYG12LUCA
ASYG14LUCA
INDICATOR PCB ASSEMBLY
K10CX-1000HSE-D0
13V
D204
UDZS6.2B
D201
SLR-343ECT
<GREEN>
D205
UDZS6.2B
D202
SL I-343DCT
<ORANGE>
D206
UDZS6.2B
D203
SLR-343ECT
<GREEN>
VCC
2
OUT
1
C204
GND
3
47/
10V
A
I C201
GP1UM271R
5V
L=250 #26 / 1061
1
2
3
4
5
6
SW201
KSHC611BT
7
8
A
A
13V
R202
47
5V
<1/4W>
C203
+
0.1
<F>
A
R201
22
<1/4W>
36
CN201
8 - JB / PL I