Maintainability; Maintainability Requirement; Trouble Shooting - AOC e941 Series Service Manual

Table of Contents

Advertisement

Service Manual
9. Maintenance Trouble treatment

9.1 Maintainability Requirement

1.
Voltmeter. & digital multimeter
2.
Oscilloscope.
3.
Pattern Generator.
4.
DDC Tool with Compatible Computer.
5.
Alignment Tool.
6.
LCD Color Analyzer.
7.
Service Manual.
8.
User Manual.
9.
repair tools etc

9.2 Trouble Shooting

Main Board---
No Power
Downloaded from ManualMonitor.com Manuals
No power
Press power key and look if
the picture is normal
NG
Please reinsert and make sure the AC
100-240V is normal ?
OK
Check 5V-CN404, 3.3V-U404-2;
1.8V-Q409/Q410,Panel-Vcc-Q405
OK
Check X401 waveform
OK
Replace U402/U401
NG
Reinsert or check the power section
NG
Check&replace
CN404,U404,Q409,Q410,Q405
NG
Replace X401
40
AOCe941series
Check flow chart
For the no power

Advertisement

Table of Contents
loading

This manual is also suitable for:

E941saE941sE941va

Table of Contents