Spray stream one-sided
Clean nozzle mouthpiece.
Insufficient vacuum performance
Check the correct positioning of the lid.
Clean seal on lid and surface on the ap-
pliance.
Clean the fluff filter.
Check suction hose for blockages;
clean if required.
Detergent pump noisy
Fill up fresh water reservoir.
Spare parts
Only use accessories and spare parts
–
which have been approved by the man-
ufacturer. The exclusive use of original
accessories and original spare parts
ensures that the appliance can be oper-
ated safely and trouble free.
At the end of the operating instructions
–
you will find a selected list of spare parts
that are often required.
For additional information about spare
–
parts, please go to the Service section
at www.kaercher.com.
Warranty
The warranty terms published by the rele-
vant sales company are applicable in each
country. We will repair potential failures of
your appliance within the warranty period
free of charge, provided that such failure is
caused by faulty material or defects in man-
ufacturing. In the event of a warranty claim
please contact your dealer or the nearest
authorized Customer Service centre.
Please submit the proof of purchase.
10
Technical specifications
Mains voltage
Frequency
Type of protection
Protective class
Rated current
Air volume (max.)
Negative pressure
(max.)
Spray pump perfor-
mance
Spray pressure
Spray pressure (max.)
Spray volume
Temperature of the
cleaning solution (max.)
Filling quantity of fresh
water
Fill volume wastewater
Length x width x height
Typical operating weight lbs (kg)
Values determined to EN 60335-2-68
Sound pressure level
L
pA
Uncertainty K
pA
Power cord
CUL
– 5
EN
V
120
Hz
1~ 60
--
IPX4
II
A
9
CFM (l/s) 123 (58)
mm
2250
(kPa)
(22.1)
W
40
psi
14.5 (0.1)
(MPa)
psi
43.5 (0.3)
(MPa)
gal/min
0.26 (1)
(l/min)
°F (°C)
122 (+50)
gal (l)
2.1 (8)
gal (l)
1.8 (7)
in (mm)
22.5 x 13.0
x 17.5
(575 x 330
x 445)
22.0 (10)
dB(A)
71
dB(A)
1
SJT 2/16 AWG
Part no.:
Cable length
6.648-222.0
33 ft (10 m)