Dissolved oxygen measurement
Optical sensor acc. to the fluorescence quenching principle, with or
without Memosens protocol
TI00387C/07/EN/13.12
71162643
Application
The continuous measurement of the dissolved oxygen
concentration is very important in many areas of water
management:
• Sewage treatment plants:Oxygen measurement and
regulation in the activated sludge basin for a highly efficient
biological cleaning process
• Water monitoring:
Oxygen measurement in rivers, lakes or seas as an indicator of
the water quality
• Water treatment:
Oxygen measurement for status monitoring of drinking water
for example (oxygen enrichment, corrosion protection etc.)
• Fish farming:
Oxygen measurement and regulation for optimum living and
growth conditions
Your benefits
• Optical technology:
– Minimum maintenance
– Maximum availability
• Sensor with digital signal processing:
– Calibration data saved in sensor
– High degree of EMC protection thanks to digital
communication with the transmitter
• Extended maintenance intervals and a high degree of long-
term stability
• Intelligent self-monitoring guarantees reliable measured
values
• No flow needed - measurement possible in still water
• COS61D - the Liquiline sensor
– Plug&Play:
Safe communication based on Memosens protocol
– Optionally with M12 plug for fast connection to the
transmitter
• COS61 - the Liquisys sensor
– Compatible with tried-and-tested COS31 with
COM2x3W:
Easy measuring point changeover to optical technology
– Compatible with COS41 with COM2x3D with conversion
kit

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Oxymax COS61

  • Page 1: Technical Information

    Technical Information Oxymax COS61/ COS61D Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle, with or without Memosens protocol Application The continuous measurement of the dissolved oxygen concentration is very important in many areas of water management: • Sewage treatment plants:Oxygen measurement and...
  • Page 2: Function And System Design

    Oxymax COS61/COS61D Function and system design Measuring principle • Sensor design: – Oxygen-sensitive molecules (markers) are integrated in an optically active layer (fluorescence layer). – The surface of the fluorescence layer is in contact with the medium. – The sensor optics are directed at the underside of the fluorescence layer.
  • Page 3 Oxymax COS61/COS61D Measuring system COS61D A complete measuring system comprises: • Oxygen sensor Oxymax COS61D • Multi-channel transmitter Liquiline CM44x • Sensor cable, optionally with M12 plug • Assembly, e.g. COA250 flow assembly, CYA112 immersion assembly or COA451 retractable assembly Optional: •...
  • Page 4 Oxymax COS61/COS61D COS61 A complete measuring system comprises: • Oxygen sensor Oxymax COS61 • Transmitter, e.g. Liquisys COM2x3-W • Special measuring cable • Assembly, e.g. COA250 flow assembly, CYA112 immersion assembly or COA451 retractable assembly Optional: • CYH112 assembly holder for immersion operation •...
  • Page 5: Power Supply

    Oxymax COS61/COS61D Power supply Electrical connection COS61D Connection methods • Sensor cable directly connected to the terminal connector of the basic module • Optional: Sensor cable plug connected to the M12 sensor socket on the underside of the device. With this type of connection, the device is already wired at the factory.
  • Page 6: Installation Conditions

    Oxymax COS61/COS61D Installation conditions Installation instructions Retractable assembly COA451 Arrow 1 shows the flow direction. The installation angle α must not exceed 90˚. The recommended installation angle is 75˚. The optical windows of the sensor have to be aligned parallel to the flow direction (α...
  • Page 7: Performance Characteristics

    Oxymax COS61/COS61D Environment Ambient temperature range –20 to +60 ˚C (0 to 140 ˚F) Storage temperature –20 to +70 ˚C (0 to 160 ˚F) at 95% relative humidity, non condensing Ingress protection COS61D • Fixed cable with terminated cable cores: IP 68 (test conditions: 10 m (33 ft) water column at 20 ˚C (68 ˚F) in 7 days)
  • Page 8: Mechanical Construction

    Oxymax COS61/COS61D Mechanical construction Design, dimensions COS61D a0013311 a0013312 With optional M12 plug With optional cleaning unit depending on cleaning unit version Design, dimensions COS61 a0004083-en a0004084-en Fixed cable version TOP68 version Endress+Hauser...
  • Page 9 Oxymax COS61/COS61D Optional cleaning unit a0013314 Optional cleaning unit Weight With cable length 7 m (23 ft): 0.7 kg (1.5 lbs.) With cable length 15 m (49 ft): 1.1 kg (2.4 lbs.) With TOP68 plug-in connection: 0.3 kg (0.66 lbs.)
  • Page 10: Certificates And Approvals

    Oxymax COS61/COS61D Certificates and approvals EMC compatibility COS61D Interference emission and interference immunity complies with EN 61326: 2005, Namur NE 21:2007 COS61 Interference emission and interference immunity complies with EN 61326: 1997 / A1: 1998 Ordering information Product page You can create a complete and valid order code by using the configurator on the internet product page.
  • Page 11 Oxymax COS61/COS61D Measuring cable COS61D CYK11 Memosens data cable • Extension cable for digital sensors with Memosens protocol • Ordering as per product structure (--> Online configurator, www.products.endress.com/cyk11) COS61 Measuring cable OMK • for use as extension cable between junction box VS and transmitter, not terminated •...
  • Page 12 TI00387C/07/EN/13.12 71162643...

This manual is also suitable for:

Oxymax cos61d

Table of Contents