12.14 AUTO COMFORT and ECO NAVI Operation
•
Area of human availability, activity level and absent is judged based on pulses by using 2 infrared sensors. The
internal setting temperature shift, fan speed and horizontal airflow direction are adjusted in order to provide
comfort environment while maintain the energy saving level.
•
AUTO COMFORT start condition:
When AUTO COMF button is pressed.
•
AUTO COMFORT stop conditions:
When AUTO COMF button is pressed again.
When unit is OFF by OFF/ON button.
When unit is OFF when OFF TIMER activates.
When unit is OFF by AUTO OFF/ON button at indoor unit.
When POWERFUL, QUIET or MILD DRY operation activates.
When ◄► button is pressed.
•
ECO NAVI start condition:
When ECO NAVI button is pressed.
•
ECO NAVI stop conditions:
When ECO NAVI button is pressed again.
When unit is OFF by OFF/ON button.
When unit is OFF when OFF TIMER activates.
When unit is OFF by AUTO OFF/ON button at indoor unit.
When POWERFUL, QUIET or MILD DRY operation activates.
When ◄► button is pressed.
•
AUTO COMFORT / ECO NAVI initialization
1
2
3
* □ Indicator ON, ■ Indicator OFF
•
Human activity judgment is as following
Signal Detection
Information Log
Area of Living Classification Judgment
Human Position Analysis
Target Area & Position Judgment
Human Activity Level Judgment
Setting Position Judgment
Initialize indication
0 – 2 seconds
2 – 3 seconds
3 – 70 seconds
Human Activity Indicator
I
II
III
IV
Repeat Step I to IV
74
□
□
■
■
■
□
■
■
■
□
□
■
□
■
■
□
■
■