General Information - Montigo B34-DV Installation Instructions

Optional fans

Advertisement

General Information

KIT #
Description
RFK1002
2 fan kit, manual control
RFK1003
2 fan kit, heat-activated control
RFK1006
4 fan kit, manual control
RFK1007
4 fan kit, heat-activated control
RFK1008
4 fan kit, manual control
RFK1009
4 fan kit, heat-activated control
Before You Begin
Please read all instructions carefully.
We strongly recommend that all electrical service work be
performed by a qualified electrical contractor.
Check to ensure that all components required for installation
are included in your package.
Installation
Accessing the Control Compartment
Remove the lower horizontal trims by placing your fingers under
bottom edge of trim next to retainer clips and pull outward. (See
Inset, Figure 1.)
Retainer clip
Trim
Pull trim outwards
from bottom
Control compartment
Figure 1. Removing the lower horizontal trims.
Page 1 of 2
Optional Fan Kit
Fan Motor Installation
Models Used With:
B34-DV, B34-DV-2
C34-DV, C34-VF
B34-DV, B34-DV-2
C34-DV, C34-VF
C38-DV
C38-DV, C42-DV
C38-DV, C42-DV
M38DV-ST
M38DV-ST
Figure 2. Cutaway view of control compartment showing fan
motor installation.
Electrical Connections
Figure 3. Electrical Connections.
Install each fan motor with the blades facing the 4" round fan
opening. Attach the mounting legs by screwing into the pilot holes
around the fan opening. Spin the fan blades by hand to ensure
they don't hit the fan opening. (See Figure 2.)
Pilot Holes
Access for
electrical connections
Mounting Legs
Plug each of the fan motor connectors into a quick connector on
the wire harness. See Figure 3.
fan motor
connector
115/1/60 Supply
G
L1 L2
Optional Fan Kits
wire harness connector
XG0630 - Rev. 05/99