2008.12.29
OUTDOOR UNIT
ELECTRICAL SPECIFICATIONS
TYPE
MODEL NAME
COOLING CAPACITY
HEATING CAPACITY
POWER SUPPLY
FREQUENCY
RUNNING CURRENT
INPUT
EER
AIR CIRCULATION HIGH
MAX CURRENT
FAN MOTOR
DISCRIMINATION
HIGH SPEED (COOL)
HIGH SPEED (HEAT)
NOISE LEVEL
COOL
HEAT
MEASUREMENT
DIMENSIONS
WEIGHT
COMPRESSOR AND REFRIGERANT
COMPRESSOR TYPE
DISCRIMINATION
WEIGHT (with oil)
STANDARD REFRIGERANT
REFRIGERANT TYPE
ADDITIONAL CHARGE
MAX PIPE LENGTH (each unit)
MAX PIPE LENGTH (total)
MIN. PIPE LENGTH (each unit)
MIN. PIPE LENGTH (total)
MAX ELEVATION (between indoor units)
MAX ELEVATION (between indoor and outdoor)
Cooling & heating multi
AOY18LMAK2
5.5 kW
6.3 kW
230 V
50 Hz
Cooling
7.3 A
Heating
7.3 A
Cooling
1.65 kW
Heating
1.65 kW
Cooling
3.33 kW/kW
Heating
3.82 kW/kW
2,800 m
10.5 A
H x W x D
650 x 830 x 320 mm
56 kg / 62 kg
Net / Gross
Hermetic type, Inverter, 4 poles,
3-phase, DC motor, Twin Rotary
TNB220FPCMT
2
AOY24LMAM2
5.8 kW
6.4 kW
230 V
50 Hz
7.6 A
7.2 A
1.73 kW
1.64 kW
3.35 kW/kW
3.90 kW/kW
3
3
/hr
2,800 m
/hr
12.5 A
MFB24JTAT
780 r.p.m.
780 r.p.m.
49 dB(A)
50 dB(A)
14.1 kg
1,900 g
R410A
Chargeless
20 m
30 m
5 m
10 m
10 m
10 m

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asy9lmacwAoy18lmak2Asy12lmacwAoy24lmam2

Table of Contents