Pentair INTELLIpH Installation And User Manual

Pentair INTELLIpH Installation And User Manual

Acid dispenser system

Advertisement

INTELLIpH
ACID DISPENSER SYSTEM
®
INSTALLATION
AND
USER'S GUIDE
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INTELLIPH
ACID DISPENSER Installation and User's Guide
®

Advertisement

Table of Contents
loading

Summary of Contents for Pentair INTELLIpH

  • Page 1 INTELLIpH ACID DISPENSER SYSTEM ® INSTALLATION USER’S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INTELLIPH ACID DISPENSER Installation and User’s Guide ®...
  • Page 2: Table Of Contents

    IntellipH Installation ..................8 Saddle Clamp Mount Installation ..............9 Pump Head Tube Replacement Instructions ..........10 Replacing the Chemical Tubing ............... 11 IntellipH Chemical Controller and Canister Replacement Parts ...... 13 READ AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL INTELLIPH ACID DISPENSER Installation and User’s Guide...
  • Page 3: Important Warnings And Safety Instructions

    IECG always wear rubber gloves and eye protection. Always add acid to water, do not add water to acid. Always work in a well-ventilated area. Splashing or spilling acid can cause severe personal injury and/or property damage. Pentair always recommends 1:1 dilution when using full strength muriatic acid. When mixing, remember to always add acid to water.
  • Page 4 Carefully pour the baking soda onto the spilled material until the fizzing stops, then mop or scoop up the residue. Leave cleanup of large spills to the experts; call your local fire department or hazardous materials spill team. INTELLIPH ACID DISPENSER Installation and User’s Guide ®...
  • Page 5: Intelliph System Overview

    0% is selected, no acid will be dispensed. All acid for the IntellipH acid dispenser system is stored in a four gallon storage canister with a built-in pump. The acid is pumped from the canister via a tube that is provided in the kit.
  • Page 6: Intelliph Controller Control Panel

    If no menu activity is detected after 30 seconds, the main screen is displayed. All menu settings are permanently saved and retained in the control panel even after the IntellipH Controller is powered ®...
  • Page 7: Operating Mode

    Operating Mode In normal operating mode, the display will alternate between “IntellipH pH CONTROLLER” and “MIN UNTIL NEXT DISPENSE”. Each message is displayed a few seconds before rotating to the next message. The “XX” is a minute countdown timer that counts down from 60 to 00.
  • Page 8: Dispense Amount

    If the water pH is low, press the LESS button to decrease the acid dispensed every hour. Likewise, if the water pH is high, press the MORE button to increase the acid dispensed every hour. IntellipH Controller is designed to maintain pH levels. If the pH is too high, utilize the ®...
  • Page 9: Superchlor Mode

    This feature replaces the MORE and LESS button on the IntelliChlor SCG. When the IntelliChlor SCG is connected to IntellipH controller, the “More” and “Less” buttons on the IntelliChlor SCG are disabled.
  • Page 10: Troubleshooting

    Cold Water is < 52°F (12.2°C) Unit will not dispense. or below. How to refill the IntellipH acid canister To Refill the IntellipH Acid Canister Always follow basic safety rules when handling acid. Read and follow the manufactures instructions on the acid container.
  • Page 11: Intelliph Installation

    If the Control System sends out a 0% output command to the IntelliChlor SCG, the cell output percentage display will be blank which indicates no chlorine is being produced. The IntellipH dispenser will display SYSTEM OFF, WILL NOT DISPENSE. No acid will be dispensed during this time.
  • Page 12: Intelliph Installation

    Choose a location on a wall or vertical surface near the IntelliChlor SCG power center (P/N 520556) and/or the EasyTouch and IntelliTouch Control System Load Center. Secure the IntellipH Controller to the surface with the three screws. WARNING! SWITCH OFF or REMOVE POWER to the IntelliChlor SCG.
  • Page 13: Saddle Clamp Mount Installation

    Insert acid tubing through the supply injector fitting cap. Connect tubing onto the acid injection fitting and tighten cap securely before turning the pump on (See diagram below). The IntellipH Acid Dispenser system is now ready for operation. ® Insert tubing from canister here...
  • Page 14: Pump Head Tube Replacement Instructions

    Before starting the tube replacement procedure, read all safety precautions on page i and ii. IMPORTANT! Replace the IntellipH pump head tube (P/N 522480) once a season (yearly). For units built before 8/2014, replace the whole pump head (P/N 521514) every season.
  • Page 15 Tube Insert tube Insert tube into slot into slot Figure 5. Figure 4. Discharge Suction Slots Figure 6. Push lock lever tab from right to left side to lock in place INTELLIPH ACID DISPENSER Installation and User’s Guide ®...
  • Page 16: Replacing The Chemical Tubing

    Prime the tubing by performing a manual dose. Verify the pump head tube stays centered on the rollers, and check for leaks. Rinse the equipment pad with water. INTELLIPH ACID DISPENSER Installation and User’s Guide ®...
  • Page 17: Intelliph Chemical Controller And Canister Replacement Parts

    Inlet of pump overtighten Tube from Outlet of pump Insert acid tubing through the supply injector fitting cap. Connect tubing onto the acid injection fitting and tighten cap securely before turning the pump on. INTELLIPH ACID DISPENSER Installation and User’s Guide ®...
  • Page 18 521505 Lid for Acid Container 521507 O-ring for Container Lid, 5 pack 521508 Suction Fitting, Black 521509 Vent Fitting, Grey 521514 SHURflo Pumphead for IntellipH Controller (prior to 2014) 521515 Motor for IntellipH with SHURflo Pumphead INTELLIPH ACID DISPENSER Installation and User’s Guide...
  • Page 19 IntellipH Controller and Chemical Canister Replacement Parts ® INTELLIPH ACID DISPENSER Installation and User’s Guide ®...
  • Page 20 1620 HAWKINS AVE., SANFORD, NC 27330 • (919) 566-8000 10951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 • (805) 553-5000 www.pentairpool.com All Pentair trademarks and logos are owned by Pentair or by one of its global affiliates. Pentair Aquatic Systems™, IntellipH , EasyTouch...