FREE STANDING STOVE CLEARANCES
A wood stove must never be installed in a hallway or near a
staircase, since it may block the way in case of fire or fail to
DIMENSION
A
B
C
D
E
F
Do not place any combustible material within 1.2m of the front
of the unit.
The clearance between the flue pipe and a wall are valid only
for vertical walls and for vertical flue pipe.
14
Backwall
Backwall
Backwall to Stove
Sidewall to Stove
Wall to corner (Angled Installation)
Backwall to Flue
Sidewall to Flue
Wall to Flue (Angled Installation)
respect required clearances. It is of utmost importance that the
clearances to combustible materials be strictly adhered to during
installation of the stove. Refer to the tables below :
CORNER INSTALLATION
Hanbury 4
CORNER INSTALLATION
Hanbury 5
750mm
725mm
600mm
600mm
700mm
625mm
781mm
757mm
717mm
732mm
731mm
657mm
The chimney connector must not pass through an attic or roof
space, closet or similar concealed space, a floor, or a ceiling.
A flue pipe crossing a combustible wall must have a minimum
clearance of 457mm.
INSTALLATION
Backwall
Backwall
Hanbury 8
700mm
700mm
700mm
742mm
842mm
742mm
6720819898 A 05/2016