3-31) Machine Compartment
Part Name
Relay O/L
3-32) Electric Box
Part Name
PBA Main
PBA INVERTER
How To Do
1. Disengage the housing connector.
2. Remove Cover Relay.
3. Remove the relay O/L with a flat-
blade screwdriver.
(Refer to the picture)
How To Do
1. Remove the 2 screw attached to
the upper left and right Case PCB
Panel with a phillips screwdriver(+).
2. Disengage all housing connectors
from the main PCB.
Before doing the above,
make sure that the unit is
CAUTION
unplugged.
3. Press the lower locking hook down
and remove the Main PBA by
pulling it out.
(Refer to the picture)
1. Remove the INVERTER PBA by
lifting the upper part of the hook up.
Disassembly and Reassembly
57
Descriptive Picture
Descriptive Picture