TH-42PX77U / TH-42PE77U
6.12. Remove the SS-Board
1. Disconnect the connectors (SS11, SS12 and SS23).
2. Disconnect the flexible cables (SS53A, SS54A, SS55A and
SS56A).
3. Remove a short-jumper connector SS34 and re-use for new
SS-Board.
4. Remove the screws (×6
6.13. Remove the C1-Board
1. Remove the tuner unit. (See section 6.4.)
2. Unlock the cable clampers to free the cable.
3. Remove the flexible cables holder fastening screws (×8
).
4. Disconnect the flexible cables (CB1, CB2, CB3 and CB4).
5. Disconnect the flexible cables (C10 and C11).
6. Remove the screws (×4
) and remove the SS-Board.
) and remove the C1-Board.
6.14. Remove the C2-Board
1. Remove the tuner unit. (See section 6.4.)
2. Unlock the cable clampers to free the cable.
3. Remove the flexible cables holder fastening screws (×8
).
4. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).
5. Disconnect the flexible cables (C20 and C21).
6. Disconnect the connector (C23).
7. Remove the screws (×4
6.15. Remove the speaker L, R
1. Disconnect the relay connector .
2. Remove the screws (×4
holder.
3. Remove the speaker L, R.
6.16. Remove the stand brackets
1. Remove the plasma panel section from the servicing stand
and lay on a flat surface such as a table (covered) with the
plasma panel surface facing downward.
2. Remove the stand brackets (left, right) fastening screws (×5
each) and remove the stand brackets (left, right).