Remote control - see Fig. 7
The maximum range of use is ~ 15metres.
The buttons on the remote control have the same function as the swiches
on the heater.
For details on the function please refer to the 'Controls' section above.
Warning: It takes time for the receiver to respond to the transmitter.
Do not press the buttons more than once within two seconds for correct
operation.
Battery information - see Fig. 7
1.
Slide open the battery cover on the back of the remote control
2.
Install AAA batteries into the remote control
3.
Replace the battery cover.
Discard leaking batteries
Dispose of batteries in the proper manner according to provincial and
local regulations.
Any battery may leak electrolyte if mixed with a different battery type, if
inserted incorrectly; if all the batteries are not replaced at the same time;
if disposed of in a fire, or if an attempt is made to charge a battery not
intended to be recharged.
Lamp Replacement - see Fig. 3, Fig. 4 and Fig. 5
The lamps are located behind the back panel. To gain access to the
lamps, the screws indicated in Fig. 3 which secure the back panel,
must be removed.
Remove and slide out panel as indicated on Fig. 4.
Remove the defective lamp by unscrewing it as shown in Fig. 5.
Replace with a 60W E14 SES Clear candle lamp. Take care not to over-
tighten the lamp.
Refit the back panel and secure with the screws.
Thermostat (T) - see Fig. 2
In order to maintain a certain room temperature, set the controller to
'max.'. Operate the appliance at full power until the required room
temperature is reached. Set back the thermostatic controller until the
appliance switches off with an audible "click". This temperature will be
kept almost constant by the thermostatic control switching on and off
automatically.Please note that the appliance can only be switched on
when the thermostat setting is higher then the room temperature.
Thermal Safety Cut-out
The built-in overheat cut-out switches off the appliance automatically in
the event of a fault. If this occurs switch off the appliance or disconnect
the mains plug from the socket. Remove any obstructions which may
have caused the overheating. After a short cooling down phase, the
appliance is ready for use again. If the fault should occur again, unplug
the appliance and contact your local dealer.
grille of the fan heater.
Instructions for fitting Coal Option - see Fig. 8
Introduction
Your fire is provided with a coal effect option. Simply follow the instruc-
tions given below.
Removal of Log Effect
Remove the screws securing the log effect assembly and slide out
(see Fig. 8).
Fitting Coal Effect
Fit the coal effect in position and secure with the screws
(see Fig. 8).
Place the coal lumps on the fuel bed. A plastic glove is provided for
handling the coal.
Note: The log effect should be stored away for possible future use.
Glen Dimplex Australia
Unit 1, 21 Lionel Road,
Mount Waverley VIC 3149
Australia
Ph: 1300 556 816
Fax: 1800 058 900
Email: sales@glendimplex.com.au
Web: www.dimplex.com.au
Specification subject to change without pior notics
Maintenance
WARNING: ALWAYS DISCONNECT FROM THE POWER SUPPLY
BEFORE ATTEMPTING ANY MAINTENANCE.
Cleaning
WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLY
BEFORE CLEANING THE HEATER.
For general cleaning use a soft clean duster – never use abrasive
cleaners. The glass viewing screen should be cleaned carefully with a
soft cloth. DO NOT use proprietary glass cleaners.
To remove any accumulation of dust or fluff the soft brush attachment of
a vacuum cleaner should occasionally be used to clean the outlet grille
of the fan heater.
Recycling
For electrical products sold within the European Community.
At the end of the electrical products useful life it should
not be disposed of with household waste. Please recycle
where facilities exist. Check with your Local Authority or
retailer for recycling advice in your country.
After Sales Service
Your product is guaranteed for one year from the date of purchase.
Within this period, we undertake to repair or exchange this product free
of charge (excluding lamps & subject to availability) provided it has been
installed and operated in accordance with these instructions.
Your rights under this guarantee are additional to your statutory rights,
which in turn are not affected by this guarantee.
Should you require after sales information or assistance with this product
please go to www.dimplex.co.uk where you will find our self help guide
by clicking on "After Sales" or ring our helpdesk on 0844 879 3588 (UK)
or 01 842 4833 (R.O.I.) .
Spare parts are also available on the website
www.dimplex.co.uk
Please retain your receipt as proof of purchase.
Glen Dimplex Austrasia Ltd
38 Harris Road,
East Tamaki, Auckland
New Zealand
Ph : 09 274 8265
Fax: 09 274 8472
Email: sales@glendimplex.co.nz
Web: www.dimplex.co.nz
UK

Advertisement

loading

This manual is also suitable for:

Stockbridge skg20blnChevalier chv20Chevalier chv20n