55. Changing the mains connections in foot control AE 010

Note:
When changing connections it is compulsory to use original PFAFF connection cables, as only these are
approved.
Removal:
Turn the foot control so that it is resting on pedal 175.
Insert a screwdriver with a wide blade on the side opposite to the cables (fig. 120).
Turn the screwdriver while removing pedal 175 upwards.
Carefully remove mains connection cables or machine cables 177 from the circuit board (fig. 120).
Loosen screw 178 or 179.
Remove mains lead cleat 180.
Remove mains connection cable or machine cable.
Refitting:
Insert new cable 177 through the bore.
Insert mains lead cleat 180 and secure with screw 173 or 174.
Connect mains connection cables or machine cables 177.
Refit pedal 175.
Use a screwdriver with a wide blade to press the pedal a little aside and insert it downwards.
Carry out a functional test.
Carry out an electrical safety test in accordance with VDE 0701 using testing appliance ABB Metrawatt
M 5013.
95