Items Required For Installation - HP StorageWorks Director 2/140 Installation Manual

Hide thumbs Also See for StorageWorks Director 2/140:
Table of Contents

Advertisement

Obtain the required fiber-optic cables (multi-mode or single-mode). Verify cable length and
required connectors.
Obtain an HP 19-inch equipment rack.
Verify that the front panel air temperature does not exceed 40 °C (104 °F) during operation.
NOTE:
Height measurements are sometimes described in rail units (Us). One U is 1.75 in.
Verify that there is space in the rack. The director is 12U (20 in) high.
Verify that the rack is stable.
If applicable, obtain the necessary remote workstations or Simple Network Management
Protocol (SNMP) workstations. Workstations are customer-supplied and connected through a
corporate or dedicated LAN.
Verify that all other equipment installed in the rack is connected to a reliable ground connection;
do not rely on connections to a branch circuit, such as a power strip.
HP recommends securing the rack mechanically to prevent it from tipping over during a natural
disaster, such as an earthquake.

Items required for installation

Locate the following items before beginning the installation procedure:
Lift device (recommended).
Director 2/140.
An HP 9000, HP 10000, HP 11000, HP system/e, or industry-standard 19-in rack, or any rack
with the following specifications:
• A minimum depth of 24.5 in.
• 19 in wide.
• A minimum opening size of 13U available (12U for the director and 1U for space
recommended for routing of cables).
Two power outlets or different branches (for redundancy).
Torque driver with cross-tip bit (for setting 22 in/lb. of torque).
Fiber-optic protective plug—For safety and port transceiver protection, fiber-optic protective plugs
must be inserted in all director ports without fiber-optic cables attached. The director is shipped
with protective plugs installed in all ports.
Null modem cable—An asynchronous RS-232 null modem cable is required to configure director
network addresses and obtain event log information through the maintenance port. The cable
has nine conductors and two DB-9 female connectors. A null modem cable specially designed
for this application is supplied with the Director 2/140.
Standard flat-tip and cross-tip Phillips screwdrivers—required to remove, replace, adjust or
tighten various FRUs, chassis, or rack components.
Electrostatic discharge (ESD) grounding cable with attached wrist strap—required when working
in and around the director card cage.