Pentair EASYTOUCH EZ100 Owner's Manual

4-function hand-held wireless remote control

Advertisement

Quick Links

EZ100 EASYTOUCH OWNER'S MANUAL
4-Function Hand-Held Wireless Remote Control
APPLICATION ............................................................................................................................................... 2
SECTION II.
KIT INCLUSION ............................................................................................................................................ 2
SECTION III.
RECEIVER ....................................................................................................................................................... 2
SECTION IV.
POWER CENTER ........................................................................................................................................... 3
SECTION V.
POWER ISOLATION CIRCUIT BOARD .................................................................................................... 3
SECTION VI.
CABLE SPLITTERS (OPTIONAL) .............................................................................................................. 3
SECTION VII.
HAND-HELD REMOTE ................................................................................................................................ 3
SECTION VIII. USING THE HAND-HELD REMOTE .......................................................................................................... 3
SECTION IX.
RECEIVER CIRCUIT BOARD ...................................................................................................................... 4
SECTION X.
AUTOMATIC COUNTDOWN CYCLE (OPTIONAL) ............................................................................... 5
SECTION XI.
CUSTOMIZING THE COMMUNICATION LINK ..................................................................................... 6
SECTION XII. TRANSMITTER BATTERY REPLACEMENT ........................................................................................... 6
SECTION XIII. TROUBLESHOOTING ................................................................................................................................... 7
Before installing this product, read and follow all warning notices and instructions which are included. Failure to
follow safety warnings and instructions can result in severe injury, death, or property damage.
Call (800) 831-7133 for additional free copies of these instructions.
Attention Installer.
This manual contains important information about the installation, operation and safe use of this
product. This information should be given to the owner/operator of this equipment.
The Hand-held remote may be used with wet hands, but should never be submersed in water, as this could
damage the unit. If accidental submersion occurs, dry unit out by removing battery cover and removing battery.
Position unit so that water can drain out. Reassemble when completely dry.
Pentair Pool Products
1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400
Rev. D 2-19-04
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS

Table of Contents

Important Notice
WARNING
IMPORTANT
1
P/N 520041

Advertisement

Table of Contents
loading

Summary of Contents for Pentair EASYTOUCH EZ100

  • Page 1: Table Of Contents

    EZ100 EASYTOUCH OWNER’S MANUAL 4-Function Hand-Held Wireless Remote Control IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SECTION I. APPLICATION ... 2 SECTION II. KIT INCLUSION ... 2 SECTION III. RECEIVER ... 2 SECTION IV. POWER CENTER ... 3 SECTION V.
  • Page 2: Section I

    SECTION I. APPLICATION Used in conjunction with Compool CP100 and EasyTouch Control Systems. Provides switching of four remote control circuits from a wireless hand-held remote. It is typically used for activating the spa circulation, and for operating three auxiliary pieces of equipment (such as lights, jet pump, air blower, waterfall, etc.) Each of the four functions on the hand-held remote has an “ON”...
  • Page 3: Power Center

    SECTION IV. POWER CENTER RISK OF ELECTRICAL SHOCK OR ELECTROCUTION If your Compool electrical panel includes circuit breakers (almond colored steel enclosure), it is also required that the main power into the home be switched off at the main circuit breaker box. Before starting the installation process, disconnect power by switching off all circuit breakers to all associated pool and spa equipment.
  • Page 4: Receiver Circuit Board

    SECTION IX. RECEIVER CIRCUIT BOARD To access the circuit board inside the Receiver, remove the two retaining screws located on the underside of the Receiver, and slide the Receiver case up and off of its backplate. On the circuit board, you will discover the following: 1) A 4-position configuration switch (designated S2), which can be used to configure an automatic countdown cycle for the Spa and/or Aux1 circuit.
  • Page 5: Automatic Countdown Cycle (Optional)

    SECTION X. AUTOMATIC COUNTDOWN CYCLE (OPTIONAL) There is a 4-position configuration switch (designated S2) located on the Receiver circuit board. This switch can be used to set a countdown cycle (time-out feature) for the Spa and/or Aux1 circuit. Once this feature has been enabled, the equipment will automatically turn off after the countdown cycle irrespective of how the circuit was turned on (by Indoor Remote, Spa-side Remote or Hand-held Remote).
  • Page 6: Customizing The Communication Link

    SECTION XI. CUSTOMIZING THE COMMUNICATION LINK The communication link between the Receiver and Hand-held Remote can be customized to prevent electrical interference. To accomplish this, there is a 10-position configuration switch located on the Receiver circuit board and inside the Hand-held Remote. Units are shipped from the factory with all switches in the “ON” position. If you wish to change this setting, use the corner of a paper clip or other blunt instrument and adjust both 10-position configuration switches to matching settings.
  • Page 7: Section Xiii. Troubleshooting

    SECTION XII. TROUBLESHOOTING Symptom POWER LED does not light. COM LINK LED does not light or blink. In normal operation LED will blink at least every 2 seconds. COMMAND LED does not light when Transmitter button(s) is pressed - unit fails to operate. Unit functions, but some circuits do not work, or operate the incorrect circuit.
  • Page 8 SAVE THESE INSTRUCTIONS. Pentair Pool Products 1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400 P/N 520041 Rev. D 2-19-04...

Table of Contents