IntelliChlor Power Center ™ (For use with ™ IntelliChlor model IC20 and IC40) Installation Guide Patents pending IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS...
Page 2
Spa, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Pentair Water Pool and Spa Inc. disclaims proprietary interest in marks and names of others.
CAUTION - Install the IntelliChlor unit a minimum of two (2) feet from the heater outlet. CAUTION - It is recommended to install a Pentair 2” CHECK VALVE (P/N 263042) between the input side of the IntelliChlor cell and the main heater output pipe.
Standard EN6100-3-2:2000, EN6100-3-3:1995 +A1:2001 • Standard EN 55014-2: 1997 +A1:2001, EN 55014-1 2000 +A1, +A2 2002 Manufacturer: Pentair Water Pool and Spa, Inc. 1620 Hawkins Ave, Sanford, NC 27330 10951 West Los Angeles Ave, Moorpark, CA 93021 Installation Steps Summary...
Power Center Overview The IntelliChlor™ system comprises of a Power Center and electrolytic Cell. The Power Center converts AC electrical current to a low voltage DC current required by the IntelliChlor electrolytic cell to operate and create chlorine for the swimming pool and spa. The Power Center is connected with the pool circulation pump electrical source so that the electrolytic cell only operates when the pool pump is on.
Operating Instructions When using a pool pump timer: The Association of Pool and Spa Professionals (APSP) recommends that all water in a residential pool pass through the filtration system at least once every 12 hours (referred to as pool water turnover). However, many factors have an effect on actual pump and filter system run times. Pool size, source of water, direct sun light, indoor/outdoor, screened and unscreened, filtration system, cold or hot weather, swimmer load, rain, organic debris, algae, etc., are all factors which contribute to either more or less pool pump and filter system run times.
Installing the Power Center Install the Power Center at eye level as close to the IntelliChlor pump and filtration as possible. The Power Center must be installed more than 8 ft. (2.44 m) from the pool edges. CAUTION: Leave sufficient clearance on all sides of the Power Center. Ensure that the 15 ft. (4.61 m) DC power cord from the Cell assembly pipe location can reach the Power Center location.
Connect AC power to the Power Center: 6. Use 12-14 AWG three conductor insulated wire for the main AC power connection. Connect the Power Center to pool pump AC power source. The Power Center should be connected to the pump motor switch or automatic timer.
Electrical Specifications and 110 VAC and 220 VAC Wiring Circuit Protection: Two-pole 20 AMP device at the electrical panel. IntelliChlor Model IC20 Input: 90-130 VAC, 50/60 Hz, 220 Watts (2 AMP) or 220-240 VAC, 50/60 Hz, 220 Watts (1 AMP). Output: 22-39 VDC @ 6 AMPS maximum from the Power Center.
Page 11
Notes IntelliChlor Power Center Installation Guide...
Page 12
Pentair Water is not, however, responsible under this warranty for any cost of shipping or transportation of the equipment or parts thereof to or from the Technical Service Department. Also, Pentair Water is not liable for any loss of time, inconvenience, incidental expenses such as telephone calls, labor or material charges incurred in connection with the removal or replacement of the equipment, or any other incidental or consequential damages.