**SLIDERS**
SERVICE GROUND
WHITE
120 VAC "COMMON"
BLACK
120 VAC "HOT"
WIRE NUT
WIRE NUT
SWITCH BOX
WIRE NUT
BLACK
BLACK
WHITE
WIRE NUT
MOTOR HARNESS AND PLUGS
N o .
1 2 3 4 N O . C O L O R U S E
N O . S Y M B O L C O L O R U S E [ S L I D E M O D E S E L E C T E D ] U S E [ S W I N G M O D E S E L E C T E D ]
N o t U s e d 1 1 5 V A C C o m m o n
1 2 3 4 5 6 7
9 D C 1 2 V 7 6 1 6 B H M 0
B r o w n R e d B l a c k W h i t e G r e e n O r a n g e O r a n g e
1 2 V D C + 1 2 V D C - ( C o m m o n )
1 2 V D C + 1 2 V D C - ( C o m m o n )
W h i t e B l a c k
1 1 5 V A C H o t
I n t e r i o r A c t i v a t i o n S e n s o r
A p p r o a c h A c t i v a t i o n S e n s o r
N o t U s e d
H o l d i n g B e a m
H o l d i n g B e a m o r S w i n g S e n s o r
N A B C O 2 4 8 9 0 1 M i c r o p r o c e s s o r C o n t r o l l e r
M o d e S w i t c h 1
R e d u c e d O p e n i n g
T h r e s h o l d S a f e t y M a t
M o d e S w i t c h 1
Power Connector (4 pin)
8 9 1 0 11 12 ( S e e M o d e S w i t c h T a b l e )
Main Harness Connector (12 pin)
Handy Terminal Connector (6 pin)
( S e e M o d e S w i t c h T a b l e )
1 2 3 4 5 6 N O . C O L O R
E n c o d e r B P h a s e U S E
M1
M o d e S w i t c h 2
M o d e S w i t c h 2
R e d O r a n g e B r o w n B l u e B l a c k Y e l l o w
M o t o r V P h a s e E n c o d e r 1 2 V D C
62 SQ
O r a n g e Y e l l o w B l u e V i o l e t G r a y
E x t e r i o r A c t i v a t i o n S e n s o r
E x t e r i o r A c t i v a t i o n S e n s o r
A l t e r n a t i n g A c t i v a t i o n
A l t e r n a t i n g A c t i v a t i o n
E n c o d e r A P h a s e
BA
O U T + O U T -
B r e a k o u t O u t p u t S w i t c h H I ( E l e c . L o c k , A i r l o c k , e t c . )
B r e a k o u t O u t p u t S w i t c h H I ( E l e c . L o c k , A i r l o c k , e t c . )
M o t o r U P h a s e E n c o d e r G r o u n d
O u t p u t S w i t c h L O ( E l e c . L o c k , A i r l o c k , e t c . )
O u t p u t S w i t c h L O ( E l e c . L o c k , A i r l o c k , e t c . )
M O D E S W I T C H T A B L E
Motor Connector (6 pin)
O p e n G n d G n d O p e n M1
MO
O p e n O p e n G n d G n d M o d e A u t o E x i t H o l d O p e n N i g h t
F o r c o n t i n u e d p r o t e c t i o n
GREEN
a g a i n s t f i r e , r e p l a c e o n l y
w i t h a f u s e o f t h e s a m e
C A U T I O N
t y p e a n d r a t i n g .
Fuse Inside
1. Adjustments to the door can only be made with a Handy Terminal.
Rating: 125V, 5A
No adjustments are available inside the control box.
Size: 5.2 x 20mm
2. Replaceable fuse located inside the control box.
W A R N I N G
3. Turn the power off prior to removing the cover.
4. This unit can not be repaired in the field. Any attempted repairs
by a n unauthorized N A B C O facility will void the warranty.
PLUG FOR HANDY TERMINAL
WHITE
WHITE
ON
RED
BLUE
RED
N I G H T
O N E W A Y
RED
BLACK
RED
RED
WHITE
BLUE
H O L D O P E N
GREEN
F U L L O P E N
BLACK
BLACK
R E D U C E D O P E N
BACK SIDE OF
SWITCH SHOWN.
ual. Failure to do so may result in property damage, or bodily injury.
MINIMUM 5 AMPERE SERVICE
PER OPERATOR
OPERATOR
MOTOR
YELLOW
NOT USED
GRAY
NOT USED
VIOLET
NOT USED
WHITE
GREEN
GREEN
BLUE
ORANGE
ORANGE
BROWN
BLACK
BROWN
RED
RED
GREEN
BLUE
BLUE
ORANGE
BLUE
ORANGE
RED
RED
NOT USED
BROWN
RED
BROWN
YELLOW
PLUG WITH BLUE
PLUG WITH BLUE
ROCKER SWITCH
JUMPER MUST BE
JUMPER MUST
BLACK
EXTENSION HARNESS
IN PLACE
BE IN PLACE
BLUE
PT. 229186
ACUSENSOR
HARNESS
RED
PT. NO. 229184
WHITE
BLUE
GREEN
BLACK
INTERIOR ACUSENSOR
EXTERIOR ACUSENSOR
PT. NO. 148902
PT. NO. 148902
BLACK
BLUE
WARNING
WIRE NUT
BROWN
BROWN
DETECTOR
EMITTER
BLACK
BROWN
LIGHT BLUE
BLACK
BLUE
"REDUCE"
LEAVE OPEN
BLACK
Teleco Brand Safety Beams
BROWN
RED
YELLOW
ACUSENSOR
HARNESS
PT. NO. 229184
1510596 Revision 5-18-04

Advertisement

Table of Contents
loading

Summary of Contents for Nabco 1175

  • Page 1 Do not install, operate or service this product unless you have read and understand the Safety Practices, Warnings, Installation and Operating Instructions contained in this man- ual. Failure to do so may result in property damage, or bodily injury. NABCO ENTRANCES INC. Phone: 877-622-2694 Fax: 888-679-3319 Technical Assistance: 1-866-622-8325 http://www.nabcoentrances.com...
  • Page 2: Table Of Contents

    Holding Beams (Activation—Hold Open) Page 10 Holding Beam (Breakout—Power Interrupt) Page 11 Diagram for connecting push plates and or card readers for Night mode. Page 12 Electric Locks—Fail Safe Page 13 Electric Locks—Fail Secure Page 14 Troubleshooting Page 15-17 NABCO ENTRANCES INC www.nabcoentrances.com...
  • Page 3: Electrical Information

    Wiring must meet all local, state, federal or other governing agency codes. Failure to do so may result in serious personal or fatal injury. Note: Since the Model 1175 Slider is predominantly wired at the factory the site installer/electrician has a relatively simple task.
  • Page 4: Typical Slider Wiring

    120 VAC "COMMON" PER OPERATOR OPERATOR BLACK 120 VAC "HOT" WIRE NUT WIRE NUT SWITCH BOX MOTOR 2110097 Telescopic Operator 219528 1175 Slider Operator WIRE NUT BLACK WIRE NUT BLACK WHITE Second pulley for YELLOW USED FOR SEQUENTIAL OPERATION HANDING HARNESS Telescopic units only.
  • Page 5: Microprocessor Controller

    Sliders Electrical Manual Microprocessor Controller NABCO ENTRANCES INC www.nabcoentrances.com...
  • Page 6 Microprocessor Main Harness Diagram FULL D O O R O P E R A T I O N TWO WAY OPEN A U T O O N L Y O F F NABCO ENTRANCES INC www.nabcoentrances.com...
  • Page 7: Dual Operator Wiring Diagrams

    Sliders Electrical Manual Dual Operator Wiring Diagram F U L L T W O W A Y O P EN NABCO ENTRANCES INC www.nabcoentrances.com...
  • Page 8: Acusensor/Acumotion

    Brown Acumotion White 1410364 Green Yellow Green Green Exterior Orange Sensor White Brown Yellow Gray Black Interior Acusensor Harness (#229184) Acusensor Extension Harness Sensor Black (#229267-01 48" Long) (#229267-02 24" Long) Brown DN 0003 Main Harness NABCO ENTRANCES INC www.nabcoentrances.com...
  • Page 9: How Door Function Modes Are Achieved Via The Rocker Switches

    One Way Traffic. The interior sensor activates the door; the exterior sensor provides threshold safety. Electric Lock is locked until an interior activation is received MODE SWITCH TABLE Mode The table at right summarizes Automatic Mode the functions as outlined above: Night Mode Hold Open Mode One Way Mode NABCO ENTRANCES INC www.nabcoentrances.com...
  • Page 10: Holding Beams (Activation-Hold Open)

    White holding beam input wire to Red (Common). This will cause the system to re-activate and hold open until the interruption is cleared. Term # & Color Optex OA-10C Beams on a GT-1175 Wiring Diagram for Holding Beams (U04 and Higher)
  • Page 11: Holding Beam (Breakout-Power Interrupt)

    This will cause the system to stop operating until the door panel is repositioned and latched. Term # & Color Optex OA-10C Beams on a GT-1175 Wiring Diagram for Breakout Beams (U04 and Higher)
  • Page 12: Diagram For Connecting Push Plates And Or Card Readers For Night Mode

    Attach the normally open contacts across the red and black wire on either the rocker or key switches. FULL TWO WAY OPEN DO O R O P E R A T I O N A U T O O N L Y O FF NABCO - 12 ENTRANCES INC www.nabcoentrances.com...
  • Page 13: Electric Locks-Fail Safe

    Sliders Electrical Manual Electric Locks—Fail Safe DN 0008 NABCO - 13 ENTRANCES INC www.nabcoentrances.com...
  • Page 14: Electric Locks-Fail Secure

    Sliders Electrical Manual Electric Locks—Fail Secure DN 0009 NABCO - 14 ENTRANCES INC www.nabcoentrances.com...
  • Page 15: Troubleshooting

    Sliders Electrical Manual Trouble Shooting NABCO - 15 ENTRANCES INC www.nabcoentrances.com...
  • Page 16 Disconnect the 12-pin connector from inside the microprocessor and install the special connector jumper tool p/n 115941 into its place. b) The system will consist of only the motor, operator and control box (Microprocessor). The Handy Terminal will be the only means of operating the door. NABCO - 16 ENTRANCES INC www.nabcoentrances.com...
  • Page 17 The holding beam connector (it has a red and white wire in it) in the main harness may be inadver- tently plugged into one of the “Power Down” (blue wires) plugs. Any vacant “Power Down” plugs should have a blue jumper installed. For technical assistance call: 866-622-8325 or engineering at: 877-622-2694 NABCO - 17 ENTRANCES INC www.nabcoentrances.com...

Table of Contents