Viessmann VITODENS 111-W Installation And Service Instructions Manual page 58

Table of Contents

Advertisement

Troubleshooting
Fault display
Displayed
System characteris-
fault code
tics
Fd
Burner blocked
FF
Burner blocked
Initiating a reset
r
58
(cont.)
Cause
Fault, burner con-
trol unit
Fault, burner con-
trol unit
Turn rotary selector "rt" to "U
RESET", until "SERV" is shown.
Within 2 s return the rotary selector to the
control range.
Measures
Check ignition electrodes
and connecting cables.
Check whether a strong
interference (EMC) field
exists near the appliance.
Press "Reset" (see
page 58).
Replace control unit if
fault persists.
Check ignition electrodes
and connecting cables.
Check whether a strong
interference (EMC) field
exists near the appliance.
Press "Reset" (see
page 58).
Replace control unit if
fault persists.