Digital Trunk Assignment; Table 5-7 Digital Trunk Assignments; Chapter 4 Programming - NEC Univerge SV9100 Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

S
2
UNIVERGE SV9100 C
ECTION
The following data programs are used when installing the GPZ-IPLE daughter board
for UNIVERGE SV9100 IP (K-CCIS).
2.1
Program/
Item No.
10-68-01
10-68-02
10-68-03
10-12-03
10-12-09
10-12-10
5-20
If any address or NIC setting is changed, the system must be reset for the changes to take
affect.

Digital Trunk Assignment

Use these programs to make digital trunk assignments when an IPLE daughter
board is installed. .

Table 5-7 Digital Trunk Assignments

Description/Selection
IP Trunk Availability -
Trunk Type
IP Trunk Availability -
Start Port
IP Trunk Availability -
Number of Ports
GCD-CP10 Network
Setup – Default Gateway
GCD-CP10 Network
Setup – IP Address
GCD-CP10 Network
Setup – Subnet Mask
P
HASSIS
ROGRAMMING
Assigned Data
0 = None
1 = SIP
2 = H.323
3 = CCIS
Default is 0
0 ~ 400
Default is 0
0 ~ 400
Default is 0
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
Default is 0.0.0.0
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
Default is 0.0.0.0
255.255.0.0
Default is 255.255.0.0
Issue 2.0
Comments
Define the IP Trunk Type
Assign the Start Port for
IP Trunks.
Define the number of
ports.
Assign the Default
Gateway for the
GCD-CP10.
When using the IPLE,
the IP Address and
Subnet Mask in
PRG 10-12-01 and
PRG 10-12-02 remain
default.
Assign the IP Address of
the IPLE.
Assign the Subnet Mask
of the IPLE
SV9100 IP K-CCIS

Advertisement

Table of Contents
loading

Table of Contents