Download Print this page
Trane ms-svu052a-en User Manual
Trane ms-svu052a-en User Manual

Trane ms-svu052a-en User Manual

Advertisement

Quick Links

Operation of wireless remote control
Name and function of wireless remote control
Note: Be sure that there are no obstructions between receiver and remote controller;
Do not drop or throw the remote control; Do not let any liquid in the remote control.
Do not put the remote control directly in sunlight or any place where it is very hot.
FAN
Signal transmitter
FAN button
This button is used for setting Fan Speed in
the sequence that goes from AUTO, Low,
Medium-Low, Medium, Medium-High, High
then back to AUTO.
NOTE: Not all fan speeds are available on all units.
AUTO
Low fan
Medium-low fan
Medium fan
Medium-high fan
High fan
Note: Dry mode uses the low fan speed.
Remote control
CLOCK
CLOCK button
CLOCK button
Press this button to set up the clock time.
The
and time display will begin to blink.
Adjust the time by pressing the
or
buttons. Press and hold the
button to change the time
value quickly. Press this button once
again to fix the time setting and exit the
clock set up.
Note: If a button is not pressed within 5
ON/OFF button
seconds (while the display is blinking) the
clock set up will exit and the setting will
Press to start or stop operation. Press
not be saved.
this button to turn on the unit. Press this
button again to turn off the unit. Turning
the unit off will cancel any sleep, quiet,
or timer functions.
MODE
MODE button
TEMP
TEMP button
TEMP button
Each time you press this button, a mode is
selected in a sequence that goes from AUTO ,
Press this button to toggle between a display
COOL, DRY, FAN and HEAT*.
of the indoor set point, indoor room
After the unit is turned on, the default operating
temperature and outdoor temperature (outdoor
mode will be AUTO. In the AUTO mode, the indoor
set point will not be displayed as the unit will
temperature is only available on select models).
automatically select the suitable operating mode
Once the unit is turned on, the indoor
and temperature set point to make the room
set point is the default temperature
temperature comfortable.
displayed.
AUTO
COOL
DRY
LIGHT
FAN
LIGHT button
HEAT
Press this button to turn the indoor unit
(
)
*only for models with heating function
display on or off. When the unit is turned
on, the default is to have the unit display on.
MS-SVU052A-EN 04/14
-1-
Operation of wireless remote control
Guide for operation- general operation
1. After the unit is installed and electricity is connected, press ON/OFF button, the unit
will start to run. (Note: When it is powered OFF, the guide louver of main unit will
close automatically.)
2. Press MODE button, select desired running mode.
3. Press
or
button, to set the desired temperature (It is unnecessary to set the temp.
at AUTO mode.)
4. Press FAN button, to set the fan speed, can select AUTO FAN, LOW,
MEDIUM-LOW, MEDIUM, MEDIUM-HIGH and HIGH. (NOTE: Not all fan speeds are available
for all units)
5. Press
or
buttons to select the swing.
Guide for operation- Optional operation
1. Press SLEEP button, to set sleep.
2. Press TIMER ON and TIMER OFF button, can set the scheduled
timer on or timer off.
or
3. Press LIGHT button, to control the light on and off of the unit display.
(This function may be not available for some units).
4. Press TURBO button, to select the ON and OFF of TURBO function.
Introduction for special function
About X-FAN function
This function allows removal of moisture on the evaporator of the indoor unit after
the unit has stopped. X-FAN is not available in AUTO, FAN or HEAT mode.
1. Having set X-FAN function on: After turning off the unit by pressing ON/OFF button
indoor fan will continue running for about 10 min at low speed. During this time
press X-FAN button again to stop the indoor fan sooner.
2. Having set X-FAN function off: After turning off the unit by pressing ON/OFF button,
the complete unit will be turned off immediately.
About AUTO RUN
When AUTO RUN mode is selected, the set point temperature will not be displayed on the
LCD. The unit will be compared with the room temperature to automatically select the suitable
running method to achieve the desired set point.
About TURBO function
When selecting this function the unit will run at the highest fan speed to cool or heat quickly
so that the room temperature reaches the desired set point as soon as possible.
-6-
Operation of wireless remote control
About lock
Press
and
buttons simultaneously to lock or unlock the keypad. If the
remote controller
is locked, the icon
flicker three times. If the keypad is unlocked, the mark will disappear.
About swing up and down
1. Press swing up and down button continuously more than two seconds,and the main unit will swing back
and forth from up to down. Release the button, and the unit will stop swinging and current
position of guide louver will be kept.
2. Under swing up and down mode, when the status is switched from off to
button again two seconds later,
within two seconds. The change of swing status will also depend on the circulation sequence stated above.
About swing left and right
1. Press swing left and right button continuously more than two seconds, the main unit will swing back
and forth from left to right. Release the button, and the unit will stop swinging and current
position of guide louver will be kept.
2. Under swing left and right mode, when the status is switched from off to
button again two seconds later,
within two seconds, the change of swing status will also depend on the circulation sequence stated above.
About switch between Fahrenheit and Centigrade
When unit is powered off, press MODE and use
Combination of " TEMP" and "CLOCK" buttons : About Energy-saving Function
Press "TEMP" and "CLOCK" simultaneously in COOL mode to start energy-saving function.
The display screen on the remote controller displays "SE". Repeat the operation to quit the function.
Combination of " TEMP" and "CLOCK" buttons : About 8
Press "TEMP" and "CLOCK" simultaneously in HEAT mode to start 8℃
Function.
The display screen
on the remote controller displays "
" 8 ℃
" (46
.
if
Fahrenheit is adopted). Repeat the operation to quit the function.
(46°F)
About Quiet function
If Auto Quiet mode has been selected, after the room temperature has reached the set point
temperature or 10 minutes later, the AC will immediately enter into the Quiet running mode, at
this time the fan speed is not adjustable.
About Sleep function
Under the Fan and Auto mode, the Sleep function cannot be set up, under DRY
mode, only Sleep 1 can be selected. Select and enter into any kind of Sleep mode, the
Quiet function will be started. Other Quiet status could be optional and turned off.
MS-SVU052A-EN 04/14
MS-SVU052A-EN 04/14
Operation of remote control
1.Lightly press the place with
will be displayed. Press any key and the lock icon will
direction to push the back cover of wireless remote control.
(As shown in Fig 1. )
2.Take out the old batteries.
3.Insert two new AAA1.5V dry batteries, and pay attention
to the polarity. (As shown in Fig 2.)
4. Attach the back cover of wireless remote control.
, press this
NOTE:
status will switch to off, press this button again
When changing the batteries, do not use old or
different batteries, otherwise, it can cause malf-
unction of the wireless remote control.
If the wireless remote control will not be used for
a long period, take the batteries out to avoid battery
leakage and damage to the wireless remote control.
, press this
status will switch to off, press this button again
Operation should be within its receiving range.
It should be placed 1m(39 inches) away from the TV
set or stereo sound sets.
buttons simultaneously to switch ℃ and ℉.
If the remote control does not operate normally, please
take the batteries out, and reinsert them 30 seconds later; if
it is still not operating ,please replace the batteries.
Heating Function
(46°F)
If the main unit needs to be remote controlled, please
(46°F)
Heating
aim the remote controller at the receiver of the main unit in order
" and a selected temperature of
to improve the receiving signal to the unit.
When the remote controller sends out signal, a mark
will flicker for about One second. The chime will sound if the main unit
receives effective signal.
-7-
Changing batteries and notices
, along the arrowhead
Fig.1
Fig.2
Sketch map for
changing batteries
MS-SVU052A-EN 04/14
-8-

Advertisement

loading

Summary of Contents for Trane ms-svu052a-en

  • Page 1 When the unit is turned so that the room temperature reaches the desired set point as soon as possible. on, the default is to have the unit display on. MS-SVU052A-EN 04/14 MS-SVU052A-EN 04/14 MS-SVU052A-EN 04/14 MS-SVU052A-EN 04/14...
  • Page 2 Sleep function is selected the temperature will decrease 1℃ button, "Mode" button, "Timer"button or "Sleep" button, the sleep (2°F) every hour, after 1℃(2°F) temperature is decreased, curve setting or enquiry status will quit similarly. this temperature will be maintained. MS-SVU052A-EN 04/14 MS-SVU052A-EN 04/14 MS-SVU052A-EN 04/14 MS-SVU052A-EN 04/14...