(3) Operation data

¡ The combinations of the indoor units is indicated by numbers. They are read as follows.
(Example) SKM22ZD-S / 22 SKM35ZD-S / 35
¡ The capacity of the indoor units is shown by rooms. If this exceeds the maximum capacity of the outdoor unit, the demand
capacity will be proportionally distributed.
¡ If units are to be combined, use the table below to make the proper selection.
Model SCM45ZD-S
(a) Heating
Indoor unit
combination
Room heating capacity (kW)
22
25
1
room
28
35
22+22
22+25
22+28
22+35
25+25
2
room
25+28
25+35
28+28
28+35
35+35
Heating capacity (kW)
A room
B room
3.2
3.4
4.0
4.5
2.65
2.65
2.5
2.9
2.4
3.1
2.2
3.4
2.75
2.75
2.6
2.9
2.4
3.3
2.8
2.8
2.6
3.2
2.95
2.95
Total capacity (kW)
Min.
Standard
Max.
0.7
3.2
3.9
0.7
3.4
4.1
0.7
4.0
4.3
0.7
4.5
4.7
1.5
5.3
7.4
1.5
5.4
7.4
1.5
5.5
7.4
1.5
5.6
7.4
1.5
5.5
7.4
1.5
5.5
7.4
1.5
5.7
7.4
1.5
5.6
7.4
1.5
5.8
7.4
1.5
5.9
7.4
9
-
-
(220/230/240V)
Power consumption (W)
Min.
Standard
Max.
200
1120
1380
200
1190
1450
200
1400
1520
200
1590
1660
450
1430
2540
450
1460
2540
450
1490
2540
450
1540
2540
450
1490
2540
450
1490
2540
450
1570
2540
450
1540
2540
450
1600
2540
450
1630
2540
Running
current (A)
Standard
5.1/4.9/4.7
5.5/5.2/5.0
6.4/6.1/5.9
7.3/7.0/6.7
6.6/6.3/6.0
6.7/6.4/6.1
6.8/6.5/6.3
7.1/6.8/6.5
6.8/6.5/6.3
6.8/6.5/6.3
7.2/6.9/6.6
7.1/6.8/6.5
7.3/7.0/6.7
7.5/7.2/6.9