Keypad Programming

To access Keypad Programming enter [ ][8][Installer's Code][ ].
To return to System Programming press [ ].

System Labels

There are 39 programmable system labels which are programmable through the Keypad or Downloading. Once a label programming section has
been entered, use the [<] and [>] Cursor keys to move left and right to get to another letter within the label. The letters of the alphabet are divided
up among the number keys 1-9 on the keypad as described below:
[<] = Display Left (Previous)
[>] = Display Right (Next)
[1] = A B C 1
[2] = D E F 2
[3] = G H I 3
[4] = J K L 4
[5] = M N O 5
For example, if you press the [4] key once, the letter "J" will appear above the cursor on the display. Press the [4] key again, the next letter "K"
will appear, and so on. If a different number is pressed, e.g. the [6] key, the cursor will automatically move to the right one space, i.e. the letter
"P". To erase a character, use the [<] [>] keys to move the cursor under the character, then press the [0] key. If the [0] key is pressed, and [<] or [>]
was the previous key pressed, the character over the cursor will be cleared. If any other key was previously pressed, then increment to and clear
the next character. While programming a label, press the [ ] key to call up an options menu. To select an option, scroll through the options using
the [<] [>] keys, then press the [ ] key to select.
SAVE
CHANGE CASE
ASCII ENTRY
CLEAR TO END
CLEAR DISPLAY
Section [001]-[034] Zone Labels
Enter a 28 character zone label for up to 32 wireless zones and 2 hardwired zones (33 & 34).
Default Value = 'ZONE----XX' where XX equals the zone number.
Section [065] Fire Alarm Labels
Enter a 28 character Fire Alarm label. Default Value = 'FIRE-ZONE'.
Section [066] Fail to Arm Event Message
Enter a 32 character Fail to Arm Event Message. Default Value = 'SYSTEM HAS ------', 'FAILED-TO-ARM---'.
Section [067] Alarm when Armed Event Message
Enter a 32 character Alarm when Armed Event Message. Default Value = 'ALARM-OCCURRED--', 'WHILE-ARMED---'.
Section [068]-[069] Command Output Label
Enter a 28 character Command Output Label label for each command Output (2 MAX).
Default Value = 'COMMAND-O/P-X-' where X equals the Command Output number.
44
[6] = P Q R 6
[7] = S T U 7
[8] = V W X 8
[9] = Y Z 9 0
[0] = SPACE
[*] = SELECT
[#] = ESCAPE
Saves the new label.
Toggles the letter entry between upper case letters (A,B,C...) and lower case letters (a,b,c...).
For entering uncommon characters. There are 255 characters.
Use the [<] [>] keys to scroll through the characters or enter a 3 digit number from 000-255.
Press the [*] key to enter the character into the label.
Clears the display from the character where the cursor was located to the end of the display.
Clears the entire label field.