HTC 650 HDX Manual page 35

Hide thumbs Also See for 650 HDX:
Table of Contents

Advertisement

Available languages

Available languages

Resetting the converter - Telemeqanique
1. Cut the current (can be done using the on/off,
emergency stop switches or by disconnecting the contact)
. Wait about one minute until the converter has gone out
3. Switch on the current
Overloading the grinder is a common fault. There are
three levels of overload
1. OCF
2. OHF
3. OLF
Things to remember.
The grinder will not start if the front/back position is
engaged when the power supply is applied
Resetting the converter - Hitachi SJ200
Press the Reset button for two seconds.
Checking the latest error code - Telemeqanique
1. Keep ESC pressed until four dashes are shown on
the display.
----.
2. Press ENTER when rdy (ready) is shown on the dis-
play.
3. SET is displayed.
Press the down arrow until SUP is shown on the dis-
play.
4. Press ENTER. FrH is shown on the display.
5. Press the down arrow until LFt (8 times) is shown.
Press ENTER.
6. The last error code is displayed.
Checking the latest error code - Hitachi SJ200
1. Press FUNC (D01 on the display)
. Press the arrow up key until you come to D0.
3. Press FUNC. The error code is shown on the display.
4. Press FUNC again. The relevant frequency is shown
when an error occurs.
5. Press FUNC again. The motor current at time of error
is shown.
6. Press FUNC again. The current at time of error is
shown.
(Voltage on the DC bus)
To view previous errors, choose D09 which matches item
 in the list above. Previous errors do not show data for
current and voltage.